PURPOSE: The distal radioulnar joint (DRUJ) capsule is assumed to be an important stabilizer of the DRUJ. There are few published data regarding the capsule and its specific contribution to stability of the DRUJ.

METHODS

We analyzed the contribution of the joint capsule to DRUJ stability in a biomechanical study consisting of collection of force/displacement data from 16 adult human cadaveric upper extremities. Each specimen was subjected to anteroposterior translation testing of the radius relative to the ulna in 3 positions of forearm rotation (neutral, 60 degrees pronation, 60 degrees supination) by serial sectioning of the DRUJ capsule. The experimental conditions tested included intact capsule, sectioned dorsal capsule, sectioned volar capsule, and repaired capsule.

RESULTS

Isolated dorsal capsule sectioning resulted in volar instability of the radius to the ulna primarily in the maximum pronated position. Significant dorsal instability of the radius was observed after isolated volar capsule sectioning in the maximum supinated position. The restabilizing effect of capsule shortening was observed near the maximums of forearm rotation. The additional stability owing to capsule shortening surpassed that of the distal radioulnar ligament at these positions.

CONCLUSIONS

We showed the effect of capsular injury on DRUJ joint stability and the restabilizing effect of capsule shortening. The importance of the capsule to DRUJ stability should be considered when planning surgical procedures to restore the unstable DRUJ.

Для цитирования: Watanabe Hiroshi, Berger Richard A, An Kai-Nan, Berglund Lawrence J, Zobitz Mark E. Stability of the distal radioulnar joint contributed by the joint capsule.. The Journal of hand surgery. 2004. DOI: 10.1016/j.jhsa.2004.06.005.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.