MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3171/2023.6.jns222695

Медицинская библиотека · Journal of neurosurgery · 2023

High-density electric source imaging patterns and outcomes following temporal lobectomy in patients with hippocampal sclerosis.

Limotai Chusak, Mokklaew Jeerawan, Sukaem Bussakorn, Jirasakuldej Suda, Prakkamakul Supada, Tepmongkol Supatporn, Bunyaratavej Krishnapundha

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

OBJECTIVE

The objective of this study was to ascertain specific patterns of electrical source imaging (ESI) that are associated with a good surgical outcome (no seizure recurrence) using 256-channel high-density (HD) electroencephalography (EEG) in patients with temporal lobe epilepsy with hippocampal sclerosis (TLE-HS) who underwent temporal lobectomy.

METHODS

Adult patients (age ≥ 18 years) were prospectively recruited from September 2016 to May 2020 at the authors' center. All patients underwent phase I presurgical evaluation and were subsequently advised to proceed with surgery based on consensus from a multidisciplinary epilepsy conference, without knowing HD-ESI results. All recruited patients were followed for at least 12 months after surgery. The outcome of interest was a status of no seizure recurrence, which was assessed at the end of the study. The association between ESI patterns and outcome was assessed using the chi-square or Fisher exact test. Associated p values as well as odds ratios and 95% CIs were reported. The diagnostic performance of the significant pattern associated with the outcome was also evaluated.

RESULTS

Fifty-eight patients with known predictors for either good or worse surgical outcomes were recruited. The mean postoperative follow-up period was 33.34 (SD 13.88) months. Forty-seven patients had sufficient interictal epileptiform discharges for HD-ESI analysis. Thirteen of these 47 patients experienced seizure recurrence. The most common source localizations were at Brodmann area (BA) 20 (inferior temporal area) and BA 21 (middle temporal area). A specific ESI pattern of BA 21 without extratemporal sources was significantly associated with no seizure recurrence (p = 0.047). This pattern had a high positive predictive value of 100% and false-positive rate of 0% associated with no seizure recurrence following the surgery.

CONCLUSIONS

A specific ESI pattern that was highly associated with no seizure recurrence following surgery was demonstrated by a 256-channel HD-EEG. If this pattern can be reproducibly proven in further studies, some TLE-HS patients may be able to proceed with surgery without further investigations.

Для цитирования: Limotai Chusak, Mokklaew Jeerawan, Sukaem Bussakorn, Jirasakuldej Suda, Prakkamakul Supada, Tepmongkol Supatporn, Bunyaratavej Krishnapundha. High-density electric source imaging patterns and outcomes following temporal lobectomy in patients with hippocampal sclerosis.. Journal of neurosurgery. 2023. DOI: 10.3171/2023.6.jns222695.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.