MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0015-0282(16)54656-1

Медицинская библиотека · Fertility and sterility · 1991

High CA-125 concentrations in peritoneal fluid of normal cyclic women with various infertility-related factors as demonstrated with two-step immunoradiometric assay.

Kruitwagen R F, Thomas C, Poels L G, Koster A M, Willemsen W N, Rolland R

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

To determine CA-125 concentrations and total amounts in peritoneal fluid (PF) of women with various infertility-related factors throughout the menstrual cycle.

DESIGN

Peritoneal fluid was obtained at laparoscopy. CA-125 was determined using the assessed two-step immunoradiometric assay (IRMA) which, in contrast to the one-step IRMA, gives valid results.

SETTING

University Hospital Nijmegen, Nijmegen, The Netherlands.

PATIENTS: One hundred six infertile women with a regular and ovulatory cycle were included.

INTERVENTIONS: None.

MAIN OUTCOME MEASURE(S): The mean PF CA-125 concentration and total amount were significantly lower during the luteal phase as compared with other phases of the menstrual cycle. No correlation was found with the presence or absence of endometriosis, adhesions, a male and/or cervical mucus infertility factor, and with patent or closed fallopian tubes.

RESULTS

Peritoneal fluid CA-125 concentrations varied from 630 to 12,000 arbitrary units/mL (mean +/- SD = 3,437 +/- 2,286). Total PF CA-125 amounts (concentration x PF volume) varied from 1,760 to 13,300 arbitrary units (mean +/- SD = 30,219 +/- 26,841).

CONCLUSIONS

CA-125 secretion into the abdominal cavity varies during the menstrual cycle. Retrograde menstruation is not the main source of CA-125 in PF.

Для цитирования: Kruitwagen R F, Thomas C, Poels L G, Koster A M, Willemsen W N, Rolland R. High CA-125 concentrations in peritoneal fluid of normal cyclic women with various infertility-related factors as demonstrated with two-step immunoradiometric assay.. Fertility and sterility. 1991. DOI: 10.1016/s0015-0282(16)54656-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.