MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1111/ajo.13340

Медицинская библиотека · The Australian & New Zealand journal of obstetrics & gynaecology · 2021

Preventing harm: A balance measure for improving the detection of fetal growth restriction.

Selvaratnam Roshan J, Wallace Euan M, Hunt Rodney W, Davey Mary-Ann

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Increasing the detection of fetal growth restriction (FGR), while reducing stillbirth, also leads to unnecessary early intervention, and associated morbidity, for normally grown babies who are incorrectly suspected of FGR.

AIMS: We sought to design a balance measure that addresses the specificity of FGR detection.

METHODS

A retrospective cohort study on all singleton births ≥32 weeks gestation in 2016 and 2017 in Victoria. We compared two balance measures for the detection of FGR, defined as the proportion of all babies iatrogenically delivered before 39 weeks gestation for suspected FGR that had a birthweight ≥10th centile (balance measure 1) or ≥25th centile (balance measure 2). Hospital level performance on each balance measure was derived and compared to an existing performance measure for severe FGR detection in Victoria.

RESULTS

Of the 38 hospitals analysed, 12 (32%) had a favourable performance on an existing indicator of FGR detection, seven (18%) hospitals had a favourable performance on balance measure 1, and 15 (39%) had a favourable performance on balance measure 2. There was a moderate correlation between hospital performance on the existing indicator and on balance measure 1 (r = 0.447, P = 0.005) but not balance measure 2 (r = -0.063, P = 0.71). There was no difference in perinatal mortality between high performing hospitals and low performing hospitals.

CONCLUSION

Introducing a balance measure into routine reporting may bring greater awareness to the unintended harm associated with increased detection of FGR.

Для цитирования: Selvaratnam Roshan J, Wallace Euan M, Hunt Rodney W, Davey Mary-Ann. Preventing harm: A balance measure for improving the detection of fetal growth restriction.. The Australian & New Zealand journal of obstetrics & gynaecology. 2021. DOI: 10.1111/ajo.13340.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.