Diagnostic Accuracy of Sonazoid-Enhanced Ultrasonography for Detection of Liver Metastasis.

Elgenidy Anas, Saad Khaled, Ibrahim Reda, Sherif Aya, Elmozugi Taher, Darwish Moaz Y, Abbas Mahmoud, Othman Yousif A, Elshimy Abdelrahman, Sheir Alyaa M, Khattab Dina H, Helal Abdallah A, Tawadros Mario M, Abuel-Naga Osama, Abdel-Rahman Hazem I, Gamal Doaa Ali, Elhoufey Amira, Dailah Hamad Ghaleb, Metwally Rami A, ElBazzar Noran, Serhan Hashem Abu

СтатьяМетаанализСистематический обзорПеревод в очереди

Аннотация

PURPOSE: To evaluate the potential clinical role and reliability of Sonazoid-enhanced ultrasound (SEUS) as a diagnostic tool for liver metastatic lesions.

METHODS

An extensive literature search was conducted across five electronic databases, PubMed, Scopus, Embase, Cochrane Library, and Web of Science, from their inception up to January 2024 to identify all studies evaluating the use of Sonazoid-enhanced ultrasonography for detecting hepatic metastases. A meta-analysis was performed to assess diagnostic accuracy using the Meta-DiSc 2.0 software.

RESULTS

A total of 31 studies were included, 16 of which were eligible for meta-analysis and diagnostic test accuracy evaluation. A total of 13 studies in the meta-analysis evaluated the diagnostic accuracy of contrast-enhanced ultrasound (CEUS) for 1347 metastatic and 1565 non-metastatic liver lesions. The pooled sensitivity and specificity for CEUS were 0.88 (95% CI: 0.82-0.92) and 0.92 (95% CI: 0.84-0.96), respectively. The combined positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 11.89 (95% CI: 5.42-26.09), 0.12 (95% CI:0.08-0.19), and 91.99 (95% CI: 32.15-263.17), respectively. Additionally, four studies of the meta-analysis assessed the diagnostic performance of contrast-enhanced intraoperative sonography (CE-IOUS) in detecting 664 metastatic and 246 non-metastatic liver lesions. The pooled sensitivity and specificity for CE-IOUS were 0.93 (95% CI: 0.82-0.97) and 0.84 (95% CI: 0.65-0.93), respectively. The aggregated positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were calculated as 5.95 (95% CI: 2.32-15.25), 0.07 (95% CI: 0.02-0.24), and 77.68 (95% CI: 10.33-583.86), respectively.

CONCLUSIONS

CE-IOUS and CEUS are reliable approaches for diagnosing liver metastatic lesions. CE-IOUS, in particular, exhibits higher accuracy in identifying liver metastatic lesions, indicating its potential effectiveness in clinical practice.

Для цитирования: Elgenidy Anas, Saad Khaled, Ibrahim Reda, Sherif Aya, Elmozugi Taher, Darwish Moaz Y, Abbas Mahmoud, Othman Yousif A, Elshimy Abdelrahman, Sheir Alyaa M, Khattab Dina H, Helal Abdallah A, Tawadros Mario M, Abuel-Naga Osama, Abdel-Rahman Hazem I, Gamal Doaa Ali, Elhoufey Amira, Dailah Hamad Ghaleb, Metwally Rami A, ElBazzar Noran, Serhan Hashem Abu. Diagnostic Accuracy of Sonazoid-Enhanced Ultrasonography for Detection of Liver Metastasis.. Medical sciences (Basel, Switzerland). 2025. DOI: 10.3390/medsci13020042.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.