MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/0002-9149(91)90925-b

Медицинская библиотека · The American journal of cardiology · 1991

Assessment of coronary artery disease using single-photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia.

Iskandrian A S, Heo J, Nguyen T, Beer S G, Cave V, Ogilby J D, Untereker W, Segal B L

Сравнительное исследованиеСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Thallium-201 myocardial imaging during dipyridamole-induced coronary hyperemia has been an accepted method for diagnosing coronary artery disease (CAD) and risk stratification. Adenosine is a powerful short-acting coronary vasodilator. Initial results of thallium imaging during adenosine infusion have been encouraging. In 132 patients with CAD and in 16 patients with normal coronary angiograms, adenosine was given intravenously at a dose of 0.14 mg/kg/min for 6 minutes and thallium-201 was injected at 3 minutes. The thallium images using single-photon emission computed tomography were abnormal in 47 of the 54 patients (87%) with 1-vessel, in 34 of 37 patients (92%) with 2-vessel and in 40 of 41 patients (98%) with 3-vessel CAD. The sensitivity was 92% in the 132 patients with CAD (95% confidence intervals, 86 to 96%). In patients with normal coronary angiograms, 14 of 16 patients had normal thallium images (specificity, 88%; 95% confidence intervals, 59 to 100%). The results were very similar when subgroups of patients were analyzed: those without prior myocardial infarction, elderly patients and women. The nature of the perfusion defects (fixed or reversible) was assessed in relation to whether the 4-hour delayed images were obtained with or without the reinjection technique. In patients who underwent conventional delayed imaging, there were more fixed perfusion defects than in patients with reinjection delayed imaging (16 vs 0%, p less than 0.0001). The adverse effects were mild, transient and well tolerated. Thus, adenosine thallium tomographic imaging provides a high degree of accuracy in the diagnosis of CAD. The use of the reinjection technique enhances the ability to detect reversible defects.

Для цитирования: Iskandrian A S, Heo J, Nguyen T, Beer S G, Cave V, Ogilby J D, Untereker W, Segal B L. Assessment of coronary artery disease using single-photon emission computed tomography with thallium-201 during adenosine-induced coronary hyperemia.. The American journal of cardiology. 1991. DOI: 10.1016/0002-9149(91)90925-b.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.