Open vs. Robot-Assisted Artificial Urinary Sphincter Implantation in Women with Stress Urinary Incontinence: A Multicenter Comparative Study.
Аннотация
Background
The artificial urinary sphincter has been an effective treatment for stress urinary incontinence caused by intrinsic sphincter deficiency in women. However, the use of this device has been limited by the technical difficulties and risks associated with the open implantation procedure. Preliminary studies using robotic techniques have shown promising results, but only one small study has compared robotic to open procedures. This study aims to compare the outcomes of robotic and open artificial urinary sphincter implantation in women with stress urinary incontinence due to intrinsic sphincter deficiency in a large multicenter cohort.
Methods
Data were collected retrospectively from female patients who underwent open or robot-assisted artificial urinary sphincter implantation from 2006 to 2020 at 12 urology departments. The primary outcome was the rate of complications within 30 days after surgery, graded using the Clavien-Dindo Classification. Perioperative and functional outcomes were compared between the two groups.
Results
A total of 135 patients were included, with 71 in the robotic group and 64 in the open group. The open group had a higher rate of intraoperative complications (27.4% vs. 12.7%; p = 0.03) and postoperative complications (46.8% vs. 15.5%; p < 0.0001). More patients in the robotic group achieved full continence (83.3% vs. 62.3%; p = 0.01). The open group had higher explantation (27.4% vs. 1.4%; p < 0.0001) and revision rates (17.5% vs. 5.6%; p = 0.02). The estimated 1-year explantation-free survival rate was higher in the robotic group. (98.6% vs. 78.3%; p = 0.001).
Conclusions
Robot-assisted implantation may reduce perioperative morbidity and improve functional outcomes compared to open implantation in women with stress urinary incontinence.