MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1371/journal.pntd.0001665

Медицинская библиотека · PLoS neglected tropical diseases · 2012

The diagnostic accuracy of serologic and molecular methods for detecting visceral leishmaniasis in HIV infected patients: meta-analysis.

Cota Gláucia Fernandes, de Sousa Marcos Roberto, Demarqui Fábio Nogueira, Rabello Ana

Сравнительное исследованиеОценочное исследованиеСтатьяМетаанализПоддержка исследования: вне правительства СШАСистематический обзорПеревод в очереди

Аннотация

BACKGROUND

Human visceral leishmaniasis (VL), a potentially fatal disease, has emerged as an important opportunistic condition in HIV infected patients. In immunocompromised patients, serological investigation is considered not an accurate diagnostic method for VL diagnosis and molecular techniques seem especially promising.

OBJECTIVE

This work is a comprehensive systematic review and meta-analysis to evaluate the accuracy of serologic and molecular tests for VL diagnosis specifically in HIV-infected patients.

METHODS

Two independent reviewers searched PubMed and LILACS databases. The quality of studies was assessed by QUADAS score. Sensitivity and specificity were pooled separately and compared with overall accuracy measures: diagnostic odds ratio (DOR) and symmetric summary receiver operating characteristic (sROC).

RESULTS

Thirty three studies recruiting 1,489 patients were included. The following tests were evaluated: Immunofluorescence Antibody Test (IFAT), Enzyme linked immunosorbent assay (ELISA), immunoblotting (Blot), direct agglutination test (DAT) and polimerase chain reaction (PCR) in whole blood and bone marrow. Most studies were carried out in Europe. Serological tests varied widely in performance, but with overall limited sensitivity. IFAT had poor sensitivity ranging from 11% to 82%. DOR (95% confidence interval) was higher for DAT 36.01 (9.95-130.29) and Blot 27.51 (9.27-81.66) than for IFAT 7.43 (3.08-1791) and ELISA 3.06 (0.71-13.10). PCR in whole blood had the highest DOR: 400.35 (58.47-2741.42). The accuracy of PCR based on Q-point was 0.95; 95%CI 0.92-0.97, which means good overall performance.

CONCLUSION

Based mainly on evidence gained by infection with Leishmania infantum chagasi, serological tests should not be used to rule out a diagnosis of VL among the HIV-infected, but a positive test at even low titers has diagnostic value when combined with the clinical case definition. Considering the available evidence, tests based on DNA detection are highly sensitive and may contribute to a diagnostic workup.

Для цитирования: Cota Gláucia Fernandes, de Sousa Marcos Roberto, Demarqui Fábio Nogueira, Rabello Ana. The diagnostic accuracy of serologic and molecular methods for detecting visceral leishmaniasis in HIV infected patients: meta-analysis.. PLoS neglected tropical diseases. 2012. DOI: 10.1371/journal.pntd.0001665.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.