MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.cca.2024.120100

Медицинская библиотека · Clinica chimica acta; international journal of clinical chemistry · 2024

Development and validation of a multiplex chip-based droplet digital PCR method for detecting CNVs in 7q11.2 and 22q11.2 regions.

Li Tianjiao, Yin Kunlun, Yang Yue, Zhou Sirui, Luo Fengming, Li Wenke, Zhao Kun, Han Bianmei, Liu Xuewen, Chen Wen

СтатьяВалидационное исследованиеПеревод в очереди

Аннотация

Copy number variations (CNVs) in the 7q11.2 and 22q11.2 chromosomal regions are major contributors to genetic disorders such as Williams-Beuren syndrome and 22q11.2 deletion/duplication syndromes. These disorders are characterized by facial anomalies, growth retardation, intellectual disabilities, and lethal cardiovascular abnormalities. Despite the development and clinical application of various rapid molecular tests, each has significant limitations. We developed a multiplex chip-based droplet digital PCR (ddPCR) method for detecting microdeletions and microduplications in the 7q11.2 and 22q11.2 regions. We evaluated its linearity and reproducibility and tested it on 100 clinical patients with congenital heart defects to further verify its clinical applicability. We successfully developed a method capable of simultaneously detecting four types of CNVs in a single assay, demonstrating high accuracy and reproducibility. Compared to traditional methods, our approach depicted 100% concordance for positive and negative results. Additionally, our method accurately quantified target gene concentrations, allowing for precise evaluation of CNVs in the target regions. This study introduces a rapid, technically straightforward, and efficient quantitative chip-based ddPCR method for the detailed classification of CNVs in the 7q11.2 and 22q11.2 regions. Our findings indicated that chip-based ddPCR can be seamlessly implemented as a first-line screening tool in routine diagnostics.

Для цитирования: Li Tianjiao, Yin Kunlun, Yang Yue, Zhou Sirui, Luo Fengming, Li Wenke, Zhao Kun, Han Bianmei, Liu Xuewen, Chen Wen. Development and validation of a multiplex chip-based droplet digital PCR method for detecting CNVs in 7q11.2 and 22q11.2 regions.. Clinica chimica acta; international journal of clinical chemistry. 2024. DOI: 10.1016/j.cca.2024.120100.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.