MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3390/children5030034

Медицинская библиотека · Children (Basel, Switzerland) · 2018

Impact of Supplemental Oxygen on Obstructive Sleep Apnea of Infants.

Das Piyush, Kashyap Rahul, Kotagal Suresh

СтатьяПеревод в очереди

Аннотация

Treatment options may be limited for infants with obstructive sleep apnea when there is no surgically correctable upper airway lesion. We therefore evaluated, retrospectively, the efficacy of low-flow oxygen as a therapeutic option for infant obstructive sleep apnea. We reviewed the medical charts of 23 infants who had undergone a therapeutic trial of low-flow oxygen during polysomnography. Split-night polysomnography was used in 21/23 subjects while 2/23 had undergone two separate, full-night polysomnography sleep architecture and respiratory findings on the baseline polysomnogram segment that was obtained in room air were compared with the segment on low-flow oxygen (0.25-1 L/min). Wilcoxon signed rank or McNemar's test were used as indicated for comparing apnea hypopnea index and measures of sleep architecture at baseline and with oxygen therapy. The mean (±SD) age of subjects was 4.8 (±2.7) months, with 52% being males. The median apnea hypopnea index fell from a baseline of 18 (range 7-43) to 3 (range 1-19; p = 0.001) on oxygen. The baseline median obstructive/mixed apnea index decreased from 2 (range 1-16) to 1 during oxygen therapy (range 0-1; p = 0.003). Additionally, a significant decrease in central apnea index (median interquartile range (IQR) 1 (0-2) vs. 0 (0-1), p = 0.002) was noted. Sleep efficiency remained unaffected, while O₂ saturation (SaO₂) average and SaO₂ nadir improved on oxygen. We were able to confirm the utility of low-flow oxygen in reducing central, obstructive, and mixed apneas and improving average oxygen saturation in infants with obstructive sleep apnea (OSA).

Для цитирования: Das Piyush, Kashyap Rahul, Kotagal Suresh. Impact of Supplemental Oxygen on Obstructive Sleep Apnea of Infants.. Children (Basel, Switzerland). 2018. DOI: 10.3390/children5030034.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.