Aviation, space, and environmental medicine · 1998
Venoconstrictive thigh cuffs impede fluid shifts during simulated microgravity.
Клиническое исследованиеСтатьяПоддержка правительства СШАНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Lindgren K N, Kraft D, Ballard R E, Tucker A, Hargens A R, New Collective Author
Аннотация
BACKGROUND: This study determined the efficacy of venoconstrictive thigh cuffs, inflated to 50 mmHg, on impeding fluid redistributions during simulated microgravity.
METHODS: There were 10 healthy male subjects who were exposed to a 2-h tilt protocol which started in the standing position, and was followed by 30 min supine, 30 min standing, 30 min supine, 30 min of -12 degrees head down tilt (HDT, to simulate microgravity), 15 min of HDT with venoconstrictive thigh cuffs inflated, a further 10 min of HDT, 5 min supine, and 10 min standing. To increase the sensitivity of the techniques in an Earth-based model, 12 degrees HDT was used to simulate microgravity effects on body fluid shifts. Volume changes were measured with anthropometric sleeve plethysmography.
RESULTS: Transition to the various tilt positions resulted in concomitant decrements in leg volume (Stand [STD] to Supine [SUP], -3.0%; SUP to HDT, -2.0%). Inflation of the venoconstrictive thigh cuffs to 50 mmHg, during simulated microgravity, resulted in a significant 3.0% increase in leg volume from that seen in HDT (p < 0.01). No significant changes in systemic cardiovascular parameters were noted during cuff inflation.
CONCLUSIONS: We conclude that venoconstrictive thigh cuffs, inflated to 50 mmHg for 15 min during 12 degrees HDT, can create a more Earth-like fluid distribution. Cuffs could potentially be used to ameliorate the symptoms of cephalad edema seen with space adaptation syndrome and to potentiate existing fluid volume countermeasure protocols.
METHODS: There were 10 healthy male subjects who were exposed to a 2-h tilt protocol which started in the standing position, and was followed by 30 min supine, 30 min standing, 30 min supine, 30 min of -12 degrees head down tilt (HDT, to simulate microgravity), 15 min of HDT with venoconstrictive thigh cuffs inflated, a further 10 min of HDT, 5 min supine, and 10 min standing. To increase the sensitivity of the techniques in an Earth-based model, 12 degrees HDT was used to simulate microgravity effects on body fluid shifts. Volume changes were measured with anthropometric sleeve plethysmography.
RESULTS: Transition to the various tilt positions resulted in concomitant decrements in leg volume (Stand [STD] to Supine [SUP], -3.0%; SUP to HDT, -2.0%). Inflation of the venoconstrictive thigh cuffs to 50 mmHg, during simulated microgravity, resulted in a significant 3.0% increase in leg volume from that seen in HDT (p < 0.01). No significant changes in systemic cardiovascular parameters were noted during cuff inflation.
CONCLUSIONS: We conclude that venoconstrictive thigh cuffs, inflated to 50 mmHg for 15 min during 12 degrees HDT, can create a more Earth-like fluid distribution. Cuffs could potentially be used to ameliorate the symptoms of cephalad edema seen with space adaptation syndrome and to potentiate existing fluid volume countermeasure protocols.