MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4103/jpbs.jpbs_265_21

Медицинская библиотека · Journal of pharmacy & bioallied sciences · 2021

Evaluation of Long-term Stability of Secondary Alveolar Bone Grafts in Cleft Palate Patients Using Multislice Computed Tomography and Three-Dimensional Printed Models: A Prospective Study.

Palankar Venkatesh, Sattur Atul, Palankar Aditi, Rajeswari S Raja, Thakur Srinath, Desai Anil Kumar

СтатьяПеревод в очереди

Аннотация

AIM: Three-dimensional (3D) printed models are contemporary volumetric bone graft assessment technique for secondary alveolar bone grafting (SABG) in cleft lip and palate (CLP) patients. The study aimed at evaluation of long-term stability of iliac autograft in SABG using multislice computed tomography (CT) and 3D-printed model-based volumetric analysis.

MATERIALS AND

METHODS

Twenty-eight patients were included in this prospective clinical study. CT image (T1) was taken after orthodontic maxillary expansion, correlating with the presurgical image. Furthermore, 3D-printed model was prepared, and volumetric assessment of graft needed was ascertained with water displacement technique. SABG was carried on with the anterior iliac crest autografting procedure. After 1-year follow-up, postoperative CT analysis (T2) was followed upon.

RESULTS

The stability of bone graft at the 1-year postoperative was found to be 43.74% with mean bone loss of 56.26% (95% confidence interval; P < 0.005). The moderate scale of CLP cases has shown statistically significant bone stability compared to that of severe and mild cases. Furthermore, the 3D-printed model has shown a significant difference to that of T1 CT imaging (P < 0.005).

CONCLUSION

Within the limitations of the study, it seems appropriate to conclude that 3D-printed models serves as better reference than CT imaging in the context of planning and execution of precise bone grafting in SABG.

Для цитирования: Palankar Venkatesh, Sattur Atul, Palankar Aditi, Rajeswari S Raja, Thakur Srinath, Desai Anil Kumar. Evaluation of Long-term Stability of Secondary Alveolar Bone Grafts in Cleft Palate Patients Using Multislice Computed Tomography and Three-Dimensional Printed Models: A Prospective Study.. Journal of pharmacy & bioallied sciences. 2021. DOI: 10.4103/jpbs.jpbs_265_21.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.