Conduction system disorders and electrocardiographic findings in COVID-19 deceased patients in 2021, Shiraz, Iran.
Аннотация
BACKGROUND
Cardiac conduction disorders and electrocardiographic (ECG) changes may occur as a manifestation of coronavirus disease 2019 (COVID-19), especially in severe cases.
AIM: To describe conduction system disorders and their association with other electrocardiographic parameters in patients who died of COVID-19.
METHODS
In this cross-sectional study, electrocardiographic and clinical data of 432 patients who expired from COVID-19 between August 1st, 2021, and December 1st, 2021, in a tertiary hospital were reviewed.
RESULTS
Among 432 patients who died from COVID-19, atrioventricular block (AVB) was found in 40 (9.3%). Among these 40 patients, 28 (6.5%) suffered from 1st degree AVB, and 12 (2.8%) suffered from complete heart block (CHB). Changes in ST-T wave, compatible with myocardial infarction or localized myocarditis, appeared in 189 (59.0%). Findings compatible with myocardial injury, such as fragmented QRS and prolonged QTc, were found in 91 patients (21.1%) and 28 patients (6.5%), respectively. In patients who died of COVID-19, conduction disorder was unrelated to any underlying medical condition. Fragmented QRS, axis deviation, and ST-T changes were significantly related to conduction system disorder in patients who died of COVID-19 (P value < 0.05).
CONCLUSION
Conduction system disorders are associated with several other ECG abnormalities, especially those indicative of myocardial ischemia or inflammation. Most patients (73.14%) who died of COVID-19 demonstrated at least one ECG abnormality parameter. Since a COVID-19 patient's ECG gives important information regarding their cardiac health, our findings can help develop a risk stratification method for at-risk COVID-19 patients in future studies.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.