DOI 10.1007/s00402-020-03343-4
A two-portal technique using a flexible reamer system is a safe and effective method for transportal anterior cruciate ligament reconstruction.
Аннотация
INTRODUCTION
A flexible reamer system (FRS) for transportal anterior cruciate ligament reconstruction (ACLR) has been developed to overcome the technical challenges of a rigid reamer system. The purpose of this study was to investigate the safety and effectiveness of the two-portal technique using an FRS by evaluating femoral tunnel geometry.
METHODS
This study included 30 patients (mean age 30 ± 12.1) who underwent transportal single-bundle ACLR. Operations were performed with the two-portal technique using an FRS. Three-dimensional computed tomography was performed for all patients 2 days after the operation. The femoral tunnel position, femoral graft bending angle, femoral tunnel length, and posterior wall breakage were evaluated. These radiologic outcomes were compared to previous literature-reported outcomes.
RESULTS
The mean distances (measured as a percentage) from the posterior wall and the intercondylar notch roof to the femoral tunnel center were 29.6 ± 5.5% and 20.1 ± 6.7%, respectively. The femoral graft bending angle (108.4° ± 6.9°) was similar to that associated with the traditional transportal technique using a rigid reamer system, but it was less acute than that associated with the three-portal technique using an FRS. The femoral tunnel length (32.8 ± 4.5 mm) was also similar to the results of the traditional transportal technique using a rigid reamer system, but it was shorter than that of three-portal technique using an FRS. The prevalence of posterior wall breakage was as low as the reported outcomes of the outside-in technique (2 cases, 6.6%).
CONCLUSIONS
The two-portal technique for transportal ACLR using an FRS can achieve comparable femoral graft bending angle and femoral tunnel length compared with the conventional three-portal technique using the rigid reamer system and had a low risk of posterior wall breakage. Therefore, the two-portal technique using the FRS can be considered a safe and effective method for transportal ACLR.
LEVEL OF EVIDENCE: Retrospective case series; level of evidence, 4.
Предметные рубрики MeSH
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.