Nuclear medicine communications · 2013
I-123-MIBG myocardial imaging in trastuzumab-based cardiotoxicity: the first experience.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Stokkel Marcel P M, de Wit-van der Veen Linda J, Boekhout Annelies
Аннотация
INTRODUCTION: Cardiotoxicity related to trastuzumab anticancer treatment poses a diagnostic challenge at early stages. The aim of the present pilot study was to assess the value of iodine-123-metaiodobenzylguanidine (I-123-MIBG) scintigraphy in breast cancer patients treated with trastuzumab who showed a decrease in their cardiac function.
MATERIALS AND METHODS: I-123-MIBG scintigraphy was performed in nine patients with decreased or significantly decreasing left ventricular ejection fraction (LVEF) during trastuzumab therapy. On the basis of planar images, 4 h heart-to-mediastinum (HMR) ratio and washout percentages (WR) were calculated.
RESULTS: I-123-MIBG scintigraphy revealed abnormal 4 h HMR and increased WR in three patients. LVEF recovery was observed in none of these patients during 3, 6, and 13 months of follow-up. In two of five patients with normal 4 h HMR the washout rates were also normal, whereas in three patients slightly increased washout rates were found. All five patients demonstrated a recovery of their LVEF value during follow-up. One patient with a normal 4 h HMR and normal WR initially showed a significant decrease in LVEF, which decreased further during follow-up. However, the LVEF value remained at 53%, which was within normal limits, after trastuzumab administration.
CONCLUSION: In this pilot study we have explored the role of I-123-MIBG scintigraphy in the assessment of trastuzumab-related cardiotoxicity and suggest that, in patients with a persistently decreasing LVEF, I-123-MIBG scintigraphy might indicate whether recovery will occur and, consequently, whether retreatment may be initiated.
MATERIALS AND METHODS: I-123-MIBG scintigraphy was performed in nine patients with decreased or significantly decreasing left ventricular ejection fraction (LVEF) during trastuzumab therapy. On the basis of planar images, 4 h heart-to-mediastinum (HMR) ratio and washout percentages (WR) were calculated.
RESULTS: I-123-MIBG scintigraphy revealed abnormal 4 h HMR and increased WR in three patients. LVEF recovery was observed in none of these patients during 3, 6, and 13 months of follow-up. In two of five patients with normal 4 h HMR the washout rates were also normal, whereas in three patients slightly increased washout rates were found. All five patients demonstrated a recovery of their LVEF value during follow-up. One patient with a normal 4 h HMR and normal WR initially showed a significant decrease in LVEF, which decreased further during follow-up. However, the LVEF value remained at 53%, which was within normal limits, after trastuzumab administration.
CONCLUSION: In this pilot study we have explored the role of I-123-MIBG scintigraphy in the assessment of trastuzumab-related cardiotoxicity and suggest that, in patients with a persistently decreasing LVEF, I-123-MIBG scintigraphy might indicate whether recovery will occur and, consequently, whether retreatment may be initiated.