BACKGROUND

Drug-induced QT-prolongation increases the risk of TdP arrhythmia attacks and sudden cardiac death. However, measuring the QT-interval and determining a precise cut-off QT/QTc value that could put a patient at risk of TdP is challenging and influenced by many factors including female sex, drug-free baseline, age, genetic predisposition, and bradycardia.

OBJECTIVES

This paper presents a novel approach for intuitively and visually monitoring QT-prolongation showing a potential risk of TdP, which can be adjusted according to patient-specific risk factors, using a pseudo-coloring technique and explainable artificial intelligence (AI).

METHODS

We extended the development and evaluation of an explainable AI-based technique- visualized using pseudo-color on the ECG signal, thus intuitively 'explaining' how its decision was made -to detect QT-prolongation showing a potential risk of TdP according to a cut-off personalized QTc value (using Bazett's ∆QTc > 60 ms relative to drug-free baseline and Bazett's QTc > 500 ms as examples), and validated its performance using a large number of ECGs (n = 5050), acquired from a clinical trial assessing the effects of four known QT-prolonging drugs versus placebo on healthy subjects. We compared this new personalized approach to our previous study that used a more general approach using the QT-nomogram.

RESULTS AND

CONCLUSIONS

The explainable AI-based algorithm can accurately detect QT-prolongation when adjusted to a personalized patient-specific cut-off QTc value showing a potential risk of TdP. Using ∆QTc > 60 ms relative to drug-free baseline and QTc > 500 ms as examples, the algorithm yielded a sensitivity of 0.95 and 0.79, and a specificity of 0.95 and 0.98, respectively. We found that adjusting pseudo-coloring according to Bazett's ∆QTc > 60 ms relative to a drug-free baseline personalized to each patient provides better sensitivity than using Bazett's QTc > 500 ms, which could underestimate a potentially clinically significant QT-prolongation with bradycardia.

Для цитирования: Alahmadi Alaa, Davies Alan, Vigo Markel, Jay Caroline. Personalized, intuitive & visual QT-prolongation monitoring using patient-specific QTc threshold with pseudo-coloring and explainable AI.. Journal of electrocardiology. 2023. DOI: 10.1016/j.jelectrocard.2023.09.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.