MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1053/rmed.2002.1379

Медицинская библиотека · Respiratory medicine · 2002

Closed pleural needle biopsy: predicting diagnostic yield by examining pleural fluid parameters.

Nusair S, Breuer R, Amir G, Berkman N

СтатьяПеревод в очереди

Аннотация

OBJECTIVE

Pleural fluid parameters that predict a diagnostic closed pleural needle biopsy were investigated.

DESIGN

A retrospective analysis.

SETTING

The Institute of Pulmonology, Hadassah University Hospital.

PATIENTS AND

METHODS

Forty-four patients who underwent closed pleural needle biopsies were included in this study. Pleural fluid values of protein, glucose, lactate dehydrogenase (LDH), pH, and white blood cell count with differential cell counts, from patients with diagnostic and non-diagnostic pleural biopsies were compared.

RESULTS

Thirteen patients (29%) had diagnostic biopsies. Malignancy was identified in 10 patients (23%), of whom 70% had adenocarcinoma. Three other patients had non-malignant specific diagnosis. LDH levels in pleural fluid from patients with diagnostic pleural biopsy were higher than in patients with non-diagnostic pleural biopsies (1436 +/- 333 U l(-1) vs. 775 +/- 109 U l(-1); P < 0.05). LDH levels less than 510 U l(-1) were highly predictive of a negative biopsy (negative predictive value of 86.6%). Follow up revealed malignancy including mesothelioma and lymphoma, in 10 of 30 (33%) patients with non-diagnostic biopsies, and one patient died of unrelated cause, while the pleural effusion either resolved, remained stable or an alternative benign process was identified in 19 patients (63%).

CONCLUSIONS

Low levels of LDH (< 510 U l(-1)) were highly predictive of a negative pleural needle biopsy. Thus, LDH may serve as a useful guide in deciding whether to perform closed pleural biopsy or to proceed to thoracoscopically guided biopsy.

Для цитирования: Nusair S, Breuer R, Amir G, Berkman N. Closed pleural needle biopsy: predicting diagnostic yield by examining pleural fluid parameters.. Respiratory medicine. 2002. DOI: 10.1053/rmed.2002.1379.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.