MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acsomega.6c06456

Медицинская библиотека · ACS omega · 2026

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples.

Yadav Aman, Birkby Arlin, Armstrong Noah, Arnob Assame, Chou Ming-Hsun, Fernandez Alma, Verhoef Aart J, Yi Zhenhuan, Gulati Siddhant, Kotnis Siddhi, Sun Qing, Kao Katy C, Wu Hung-Jen

СтатьяПеревод в очереди

Аннотация

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Для цитирования: Yadav Aman, Birkby Arlin, Armstrong Noah, Arnob Assame, Chou Ming-Hsun, Fernandez Alma, Verhoef Aart J, Yi Zhenhuan, Gulati Siddhant, Kotnis Siddhi, Sun Qing, Kao Katy C, Wu Hung-Jen. Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples.. ACS omega. 2026. DOI: 10.1021/acsomega.6c06456.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.