BACKGROUND

Left atrial appendage occlusion (LAAO) procedures are widely guided by standard transesophageal echocardiography (TEE) probes, requiring general anesthesia in most patients. The use of miniaturized TEE probes allows for LAAO guidance under local anesthesia and offers an attractive imaging alternative to standard TEE probes.

OBJECTIVES

The aim of this study was to assess the safety and efficacy of miniaturized TEE probes for procedural guidance of LAAO.

METHODS

Multicenter retrospective observational study of LAAO procedures performed under miniaturized TEE guidance and conscious sedation. The primary efficacy endpoint was technical success. The secondary efficacy endpoint was procedural success (technical success without major periprocedural complications). The safety outcome was a composite of major periprocedural complications.

RESULTS

A total of 546 consecutive LAAO procedures were performed in 5 European centers. Technical success was achieved in 534 (98.0%) patients. Sixteen major periprocedural complications occurred in 15 (2.9%) patients, yielding a procedural success rate of 97.0%. Conversion to general anesthesia was required in 4 (0.7%) patients. Short-term imaging follow-up was available in 422 patients with an incidence of major (>5 mm) TEE-detected residual leaks of 0.7%, complete LAA occlusion of 82.2% on cardiac computed tomography, and device-related thrombus of 5%. As compared with procedural 2-dimensional imaging for device sizing, preprocedural assessment by 3-dimensional imaging resulted in improved technical success (100% vs 95.0%; P < 0.001).

CONCLUSIONS

LAAO under conscious sedation and miniaturized TEE guidance is safe and feasible with a high rate of technical success and a low rate of periprocedural complications.

Для цитирования: Aminian Adel, Leduc Nina, Freixa Xavier, Swaans Martin J, Ben Yedder Mohamed, Maarse Moniek, Sanchis Laura, Cepas-Guillen Pedro, Cruz-González Ignacio, Blanco-Fernandez Fabian, Eschalier Romain, Boersma Lucas V A. Left Atrial Appendage Occlusion Under Miniaturized Transesophageal Echocardiographic Guidance and Conscious Sedation: Multicenter European Experience.. JACC. Cardiovascular interventions. 2023. DOI: 10.1016/j.jcin.2023.06.007.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.