Archives of disease in childhood. Fetal and neonatal edition · 2019
Effect of monitor positioning on visual attention and situation awareness during neonatal resuscitation: a randomised simulation study.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Law Brenda Hiu Yan, Cheung Po-Yin, van Os Sylvia, Fray Caroline, Schmölzer Georg M
Аннотация
OBJECTIVES: To compare situation awareness (SA), visual attention (VA) and protocol adherence in simulated neonatal resuscitations using two different monitor positions.
DESIGN: Randomised controlled simulation study.
SETTINGS: Simulation lab at the Royal Alexandra Hospital, Edmonton, Canada.
PARTICIPANTS: Healthcare providers (HCPs) with Neonatal Resuscitation Program (NRP) certification within the last 2 years and trained in neonatal endotracheal intubations.
INTERVENTION: HCPs were randomised to either central (eye-level on the radiant warmer) or peripheral (above eye-level, wall-mounted) monitor positions. Each led a complex resuscitation with a high-fidelity mannequin and a standardised assistant. To measure SA, situation awareness global assessment tool (SAGAT) was used, where simulations were paused at three predetermined points, with five questions asked each pause. Videos were analysed for SAGAT and adherence to a NRP checklist. Eye-tracking glasses recorded participants' VA.
MAIN OUTCOME MEASURE: The main outcome was SA as measured by composite SAGAT score. Secondary outcomes included VA and adherence to NRP checklist.
RESULTS: Thirty simulations were performed; 29 were completed per protocol and analysed. Twenty-two eye-tracking recordings were of sufficient quality and analysed. Median composite SAGAT was 11.5/15 central versus 11/15 peripheral, p=0.56. Checklist scores 46/50 central versus 46/50 peripheral, p=0.75. Most VA was directed at the mannequin (30.6% central vs 34.1% peripheral, p=0.76), and the monitor (28.7% central vs 20.5% peripheral, p=0.06).
CONCLUSIONS: Simulation, SAGAT and eye-tracking can be used to evaluate human factors of neonatal resuscitation. During simulated neonatal resuscitation, monitor position did not affect SA, VA or protocol adherence.
DESIGN: Randomised controlled simulation study.
SETTINGS: Simulation lab at the Royal Alexandra Hospital, Edmonton, Canada.
PARTICIPANTS: Healthcare providers (HCPs) with Neonatal Resuscitation Program (NRP) certification within the last 2 years and trained in neonatal endotracheal intubations.
INTERVENTION: HCPs were randomised to either central (eye-level on the radiant warmer) or peripheral (above eye-level, wall-mounted) monitor positions. Each led a complex resuscitation with a high-fidelity mannequin and a standardised assistant. To measure SA, situation awareness global assessment tool (SAGAT) was used, where simulations were paused at three predetermined points, with five questions asked each pause. Videos were analysed for SAGAT and adherence to a NRP checklist. Eye-tracking glasses recorded participants' VA.
MAIN OUTCOME MEASURE: The main outcome was SA as measured by composite SAGAT score. Secondary outcomes included VA and adherence to NRP checklist.
RESULTS: Thirty simulations were performed; 29 were completed per protocol and analysed. Twenty-two eye-tracking recordings were of sufficient quality and analysed. Median composite SAGAT was 11.5/15 central versus 11/15 peripheral, p=0.56. Checklist scores 46/50 central versus 46/50 peripheral, p=0.75. Most VA was directed at the mannequin (30.6% central vs 34.1% peripheral, p=0.76), and the monitor (28.7% central vs 20.5% peripheral, p=0.06).