MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/07853890.2025.2519683

Медицинская библиотека · Annals of medicine · 2025

Use of view-adjustable video laryngeal mask versus endotracheal intubation for airway management during anaesthesia for arthroscopic surgery: a randomized trial.

Geng Chun-Jing, Su Guang-Lei, Deng Ying, Cong Zhu-Kai, Feng Dan-Dan, Zhang Si-Yuan, Cao Hai-Li, Zeng Hong

СтатьяРандомизированное исследованиеСравнительное исследованиеПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

INTRODUCTION

The objective of this study was to compare the practicality and efficacy of utilizing a view-adjustable video laryngeal mask (SafeLM) versus endotracheal intubation (ETI) in the context of arthroscopic shoulder surgery.

PATIENTS AND

METHODS

A randomized controlled trial enrolled 100 patients undergoing arthroscopic shoulder surgery, randomly assigned to the SafeLM group (n = 50) or ETI group (n = 50). The primary outcome measure was hemodynamic parameters, while mechanical ventilation parameters, complications, and the quality of anaesthesia recovery were considered as secondary outcomes. These parameters were then compared between the two groups.

RESULTS

During the intubation and extubation procedures, the SafeLM group demonstrated significantly lower mean arterial pressure and heart rate compared to the ETI group (p < 0.001). Furthermore, the airway pressure at T2 and T3 was notably lower in the SafeLM group compared to the ETI group (p < 0.001). However, there were no statistically significant differences in oxygen saturation observed between the two groups at any time point. Both groups were equally capable of quickly establishing a surgical airway when necessary. Notably, a smaller proportion of patients in the SafeLM group exhibited negative reactions during tube removal. Additionally, there was a statistically significant difference in the occurrence of post-operative sore throat, difficulty swallowing, choking, and coughing between the two groups (p < 0.001).

CONCLUSIONS

The utilization of SafeLM may result in enhanced regulation of blood pressure and heart rate among patients who undergo arthroscopic surgery for the shoulder while in the side decubitus position.

Для цитирования: Geng Chun-Jing, Su Guang-Lei, Deng Ying, Cong Zhu-Kai, Feng Dan-Dan, Zhang Si-Yuan, Cao Hai-Li, Zeng Hong. Use of view-adjustable video laryngeal mask versus endotracheal intubation for airway management during anaesthesia for arthroscopic surgery: a randomized trial.. Annals of medicine. 2025. DOI: 10.1080/07853890.2025.2519683.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.