MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/rti.0000000000000330

Медицинская библиотека · Journal of thoracic imaging · 2018

Technological Advancements in Echocardiographic Assessment of Thoracic Aortic Dilatation: Head to Head Comparison Among Multidetector Computed Tomography, 2-Dimensional, and 3-Dimensional Echocardiography Measurements.

Ghulam Ali Sarah, Fusini Laura, Dalla Cia Alessia, Tamborini Gloria, Gripari Paola, Muratori Manuela, Mancini Maria E, Annoni Andrea, Formenti Alberto, Pepi Mauro

Сравнительное исследованиеСтатьяПеревод в очереди

Аннотация

PURPOSE: The aim of this study was to evaluate the feasibility and accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (2DTTE, 3DTTE) versus multidetector computed tomography (MDCT) in patients with ascending aortic (AA) dilation.

MATERIALS AND

METHODS

Fifty consecutive patients with AA dilation were evaluated by 2DTTE, X-plane (XP) 3DTTE, and MDCT. Aorta diameters were measured at aortic annulus, aortic root (SIN), sinotubular junction, AA, aortic arch before the prebrachiocephalic artery (PRE), and before left subclavian artery (INTRA). Leading edge-to-leading edge (L-L) and inner-to-inner (I-I) measurements were compared with MDCT data.

RESULTS

Feasibility, quality of imaging, and accuracy was high with all echocardiographic methods. Specifically for MDCT maximum SIN diameter, the best correlation and agreement was obtained using XP maximum diameter at 3DTTE (MDCT: 44.8±7.4 mm vs. XP: 44.4±7.4 mm; r=0.975; bias=-0.4 mm). The same was true for AA maximum diameter at MDCT (MDCT: 46.6±8.1 mm vs. XP: 47.5±8.1 mm; r=0.991; bias=0.1 mm). For aortic arch the best correlation and agreement with MDCT were as follows: 2DTTE L-L diameter for arch PRE (MDCT: 37.9±5.3 mm vs. TTE: 36.6±4.5 mm; r=0.927; bias=-0.9 mm) and MDCT minimum diameter with XP minimum diameter for arch INTRA (MDCT: 28.2±5.0 mm vs. TTE 28.8±4.7 mm; r=0.939; bias=-0.3 mm).

CONCLUSION

In patients with aortic dilatation or aneurysm, new techniques (mainly 2D-3D probes allowing XP views) facilitate accuracy of aortic measurements at different sites of the vessel and allow standardization of analysis to better compare with MDCT.

Для цитирования: Ghulam Ali Sarah, Fusini Laura, Dalla Cia Alessia, Tamborini Gloria, Gripari Paola, Muratori Manuela, Mancini Maria E, Annoni Andrea, Formenti Alberto, Pepi Mauro. Technological Advancements in Echocardiographic Assessment of Thoracic Aortic Dilatation: Head to Head Comparison Among Multidetector Computed Tomography, 2-Dimensional, and 3-Dimensional Echocardiography Measurements.. Journal of thoracic imaging. 2018. DOI: 10.1097/rti.0000000000000330.