MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/ehjacc/zuac156

Медицинская библиотека · European heart journal. Acute cardiovascular care · 2023

Artificial intelligence-augmented electrocardiography for left ventricular systolic dysfunction in patients undergoing high-sensitivity cardiac troponin T.

De Michieli Laura, Knott Jonathan D, Attia Zachi I, Ola Olatunde, Mehta Ramila A, Akula Ashok, Hodge David O, Gulati Rajiv, Friedman Paul A, Jaffe Allan S, Sandoval Yader

СтатьяПеревод в очереди

Аннотация

AIMS: Our goal was to evaluate a previously validated artificial intelligence-augmented electrocardiography (AI-ECG) screening tool for left ventricular systolic dysfunction (LVSD) in patients undergoing high-sensitivity-cardiac troponin T (hs-cTnT).

METHODS AND

RESULTS

Retrospective application of AI-ECG for LVSD in emergency department (ED) patients undergoing hs-cTnT. AI-ECG scores (0-1) for probability of LVSD (left ventricular ejection fraction ≤ 35%) were obtained. An AI-ECG score ≥0.256 indicates a positive screen. The primary endpoint was a composite of post-discharge major adverse cardiovascular events (MACEs) at two years follow-up. Among 1977 patients, 248 (13%) had a positive AI-ECG. When compared with patients with a negative AI-ECG, those with a positive AI-ECG had a higher risk for MACE [48 vs. 21%, P < 0.0001, adjusted hazard ratio (HR) 1.39, 95% confidence interval (CI) 1.11-1.75]. This was largely because of a higher rate of deaths (32 vs. 14%, P < 0.0001; adjusted HR 1.26, 95% 0.95-1.66) and heart failure hospitalizations (26 vs. 6.1%, P < 0.001; adjusted HR 1.75, 95% CI 1.25-2.45). Together, hs-cTnT and AI-ECG resulted in the following MACE rates and adjusted HRs: hs-cTnT < 99th percentile and negative AI-ECG: 116/1176 (11%; reference), hs-cTnT < 99th percentile and positive AI-ECG: 28/107 (26%; adjusted HR 1.54, 95% CI 1.01-2.36), hs-cTnT > 99th percentile and negative AI-ECG: 233/553 (42%; adjusted HR 2.12, 95% CI 1.66, 2.70), and hs-cTnT > 99th percentile and positive AI-ECG: 91/141 (65%; adjusted HR 2.83, 95% CI 2.06, 3.87).

CONCLUSION

Among ED patients evaluated with hs-cTnT, a positive AI-ECG for LVSD identifies patients at high risk for MACE. The conjoint use of hs-cTnT and AI-ECG facilitates risk stratification.

Для цитирования: De Michieli Laura, Knott Jonathan D, Attia Zachi I, Ola Olatunde, Mehta Ramila A, Akula Ashok, Hodge David O, Gulati Rajiv, Friedman Paul A, Jaffe Allan S, Sandoval Yader. Artificial intelligence-augmented electrocardiography for left ventricular systolic dysfunction in patients undergoing high-sensitivity cardiac troponin T.. European heart journal. Acute cardiovascular care. 2023. DOI: 10.1093/ehjacc/zuac156.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.