MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.medengphy.2022.103757

Медицинская библиотека · Medical engineering & physics · 2022

Design and development of a novel double-chamber syringe concept for venous catheterization.

Bastos Lourenço, Marques Rita, Silva Joana, Freitas Ricardo, Marques Ângelo, Gonçalves Nuno, Cortez Sara, Coelho Alberta, Sousa Liliana, Parreira Pedro, Silva Bruno, Carneiro Filipa

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

This paper presents the optimization process for the development of an innovative double chamber syringe. Several aspects are involved such as design, functionality, fluid-structure interaction and friction between solids. To assist in the development of this medical device, a numerical based methodology was developed and validated in order to predict the syringe´s functionality, as well as its production by injection molding. The mechanical and flow behavior, during the filling and administration of medicine and washing solutions, were numerically modelled using the commercial software ABAQUS and FLUENT, respectively. The injection molding process was analyzed using the software MOLDFLOW. The aim was to evaluate the feasibility of the proposed concept in terms of mechanical design, fluid flow and production process behavior. By highlighting critical design issues in this way, it was possible to identify promising geometric changes and, consequently, optimize iteratively the syringe's design, until all the defined requirements are fulfilled. This iterative process based on numerical simulations proved to be a powerful tool for product development that generated fast and accurate results without the need to produce multiple prototypes.

Для цитирования: Bastos Lourenço, Marques Rita, Silva Joana, Freitas Ricardo, Marques Ângelo, Gonçalves Nuno, Cortez Sara, Coelho Alberta, Sousa Liliana, Parreira Pedro, Silva Bruno, Carneiro Filipa. Design and development of a novel double-chamber syringe concept for venous catheterization.. Medical engineering & physics. 2022. DOI: 10.1016/j.medengphy.2022.103757.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.