Biomechanical Comparison of Metal Versus Suture and Screw Tension Band Technique for Olecranon Fractures.
Аннотация
PURPOSE: Suture that approaches the strength of metal wire is now commonly used in many orthopedic applications. This study aimed to compare the strength of a suture and screw tension band fixation of olecranon fractures with the established method K-wire and metal tension band technique.
METHODS
A biomechanical model was created using 10 matched pair cadaver arms. A transverse olecranon osteotomy was made and repaired with either a standard 1.6-mm K-wire and 18-gauge metal tension-band construct or a tension band composed of two #2 ultra-high molecular weight polyethylene sutures combined with a 4.5-mm headless compression screw. Constructs were loaded through the triceps tendon and first subjected to cyclic loading to 300 N, followed by load-to-failure testing. Failure was defined as a fracture gap of 2 mm or more.
RESULTS
During cyclic loading, 2 of 5 arms in the metal tension band group failed, whereas none in the suture/screw group did. The suture/screw construct was, on average, 219N stronger than the K-wire/metal tension band construct.
CONCLUSIONS
The suture/screw olecranon tension band construct appears to be stronger than the commonly used metal tension band and should be considered as a suitable alternative for fixation of olecranon fractures.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.