MedElevator Войти в исследования
← Поиск публикаций

DOI 10.3389/fphys.2023.1257682

Медицинская библиотека · Frontiers in physiology · 2023

Electrophysiological basis of cardiac arrhythmia in a mouse model of myotonic dystrophy type 1.

Ginjupalli Vamsi Krishna Murthy, Cupelli Michael, Reisqs Jean-Baptiste, Sleiman Yvonne, El-Sherif Nabil, Gourdon Genevieve, Puymirat Jack, Chahine Mohamed, Boutjdir Mohamed

СтатьяПеревод в очереди

Аннотация

Introduction

Myotonic dystrophy type 1 (DM1) is a multisystemic genetic disorder caused by the increased number of CTG repeats in 3' UTR of Dystrophia Myotonia Protein Kinase (DMPK) gene. DM1 patients experience conduction abnormalities as well as atrial and ventricular arrhythmias with increased susceptibility to sudden cardiac death. The ionic basis of these electrical abnormalities is poorly understood.

Methods

We evaluated the surface electrocardiogram (ECG) and key ion currents underlying the action potential (AP) in a mouse model of DM1, DMSXL, which express over 1000 CTG repeats. Sodium current (INa), L-type calcium current (ICaL), transient outward potassium current (Ito), and APs were recorded using the patch-clamp technique.

Results

Arrhythmic events on the ECG including sinus bradycardia, conduction defects, and premature ventricular and atrial arrhythmias were observed in DMSXL homozygous mice but not in WT mice. PR interval shortening was observed in homozygous mice while ECG parameters such as QRS duration, and QTc did not change. Further, flecainide prolonged PR, QRS, and QTc visually in DMSXL homozygous mice. At the single ventricular myocyte level, we observed a reduced current density for Ito and ICaL with a positive shift in steady state activation of L-type calcium channels carrying ICaL in DMSXL homozygous mice compared with WT mice. INa densities and action potential duration did not change between DMSXL and WT mice.

Conclusion

The reduced current densities of Ito, and ICaL and alterations in gating properties in L-type calcium channels may contribute to the ECG abnormalities in the DMSXL mouse model of DM1. These findings open new avenues for novel targeted therapeutics.

Для цитирования: Ginjupalli Vamsi Krishna Murthy, Cupelli Michael, Reisqs Jean-Baptiste, Sleiman Yvonne, El-Sherif Nabil, Gourdon Genevieve, Puymirat Jack, Chahine Mohamed, Boutjdir Mohamed. Electrophysiological basis of cardiac arrhythmia in a mouse model of myotonic dystrophy type 1.. Frontiers in physiology. 2023. DOI: 10.3389/fphys.2023.1257682.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.