MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0894-7317(14)80313-1

Медицинская библиотека · Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 1990

Influence of Doppler sample volume location on the assessment of changes in mitral inflow velocity profiles.

Dittrich H C, Blanchard D G, Wheeler K A, McCann H A, Donaghey L B

СтатьяПеревод в очереди

Аннотация

Previous studies that have validated Doppler indexes of mitral inflow have used pulsed wave sample volume locations either at the level of the mitral valve anulus or at the tips of the mitral valve leaflets. Although significant differences between absolute values for peak velocities and velocity time integrals at these sample volume locations have previously been reported, no information exists that has compared changes in inflow profiles after an intervention to improve left ventricular filling. To address this question, 13 patients with severe pulmonary hypertension (mean pulmonary artery pressure, 50 +/- 13 mm Hg) caused by chronic thromboembolic disease were studied with use of Doppler echocardiography immediately before and after surgical reduction of pulmonary hypertension (pulmonary vascular resistance decreased from 916 +/- 413 to 233 +/- 89 dynes.sec.cm5). This clinical model has been shown to have abnormal mitral inflow velocity profiles that improve markedly after surgery. Doppler measures of early and late peak velocities were significantly lower both before and after surgery when sampling at the mitral anulus compared with the leaflet tips, although late filling parameters and the deceleration of early flow velocity tended to differ little. With surgery, the significant increase in peak early velocity and the ratio of early to late velocity was present regardless of the sample volume location (peak E at leaflet tips, 47.1 +/- 16.0 to 68.9 +/- 15.4 [p less than 0.001], and at anulus, 40.7 +/- 11.3 to 56.2 +/- 14.6 cm/sec [p less than 0.001]; peak E/A at leaflet tips, 0.95 +/- 0.4 to 1.55 +/- 0.9, and at anulus, 0.78 +/- 0.3 to 1.32 +/- 0.7 [both p less than 0.02]).(ABSTRACT TRUNCATED AT 250 WORDS)

Для цитирования: Dittrich H C, Blanchard D G, Wheeler K A, McCann H A, Donaghey L B. Influence of Doppler sample volume location on the assessment of changes in mitral inflow velocity profiles.. Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography. 1990. DOI: 10.1016/s0894-7317(14)80313-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.