Journal of the Saudi Heart Association · 2018
Development of tissue Doppler-derived predictors of hemodynamically significant patent ductus arteriosus and the ability to incorporate it in targeted neonatal echocardiography protocol.
СтатьяНазвание и аннотация: Перевод в очереди
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…
Ошибки и ограничения
История · было → стало
Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.
El-Saiedi Sonia, AbdelMassih Antoine Fakhry, Sedky Yasser, Malash Amr, Hussain Nouran, Alfons Monica, Essam Rana
Аннотация
BACKGROUND: Hemodynamically significant (HS) patent ductus arteriosus (PDA) is a significant cause of mortality in preterm neonates. Early detection of HS PDA and pre-symptomatic closure may help in avoiding complications. For this to happen, easily performed predictors must be available; the aim of this paper is to test the reliability and repeatability of tissue Doppler-derived parameters for prediction of HS PDA.
METHODS: Preterm neonates <32 weeks were screened with echocardiography at Day 3 of life; 80 neonates with PDA were classified into HS group and hemodynamically insignificant (HIS) group based on benchmark parameter namely left ventricular outflow to superior vena caval flow ratio (LVO/SVC), and a ratio ≥4 was considered predictive of HS PDA. Tissue Doppler-derived left ventricular myocardial systolic and diastolic velocities were also performed.
RESULTS: In total, 105 neonates (55 among HS and 60 among HIS groups) were included in the study. Septal systolic velocity (S') proved of high sensitivity (100%) in the prediction of HS PDA; nevertheless, it proved to be more repeatable than the initially discriminating parameter (LVO/SVC) with a Kappa of 0.92.
CONCLUSION: This study concludes that septal S' can be reliably used even by neonatologists for pre-symptomatic detection of HS PDA. This may also indicate the need of adding tissue Doppler parameters to the standard protocol of targeted neonatal echocardiography.
METHODS: Preterm neonates <32 weeks were screened with echocardiography at Day 3 of life; 80 neonates with PDA were classified into HS group and hemodynamically insignificant (HIS) group based on benchmark parameter namely left ventricular outflow to superior vena caval flow ratio (LVO/SVC), and a ratio ≥4 was considered predictive of HS PDA. Tissue Doppler-derived left ventricular myocardial systolic and diastolic velocities were also performed.
RESULTS: In total, 105 neonates (55 among HS and 60 among HIS groups) were included in the study. Septal systolic velocity (S') proved of high sensitivity (100%) in the prediction of HS PDA; nevertheless, it proved to be more repeatable than the initially discriminating parameter (LVO/SVC) with a Kappa of 0.92.
CONCLUSION: This study concludes that septal S' can be reliably used even by neonatologists for pre-symptomatic detection of HS PDA. This may also indicate the need of adding tissue Doppler parameters to the standard protocol of targeted neonatal echocardiography.