MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/infdis/jiac049

Медицинская библиотека · The Journal of infectious diseases · 2022

Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review.

Catlett Beth, Hajarizadeh Behzad, Cunningham Evan, Wolfson-Stofko Brett, Wheeler Alice, Khandaker-Hussain Benazir, Feld Jordan J, Martró Elisa, Chevaliez Stéphane, Pawlotsky Jean Michel, Bharat Chrianna, Cunningham Philip H, Dore Gregory J, Applegate Tanya, Grebely Jason

СтатьяМетаанализСистематический обзорПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

BACKGROUND

Finger-stick point-of-care and dried blood spot (DBS) hepatitis C virus (HCV) RNA testing increases testing uptake and linkage to care. This systematic review evaluated the diagnostic accuracy of point-of-care testing and DBS to detect HCV RNA.

METHODS

Bibliographic databases and conference presentations were searched for eligible studies. Meta-analysis was used to pool estimates.

RESULTS

Of 359 articles identified, 43 studies were eligible and included. When comparing the Xpert HCV Viral Load Fingerstick assay to venous blood samples (7 studies with 987 samples), the sensitivity and specificity for HCV RNA detection was 99% (95% confidence interval [CI], 97%-99%) and 99% (95% CI, 94%-100%) and for HCV RNA quantification was 100% (95% CI, 93%-100%) and 100% (95% CI, 94%-100%). The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing was 6% (95% CI, 3%-11%). When comparing DBS to venous blood samples (28 studies with 3988 samples) the sensitivity and specificity for HCV RNA detection was 97% (95% CI, 95%-98%) and 100% (95% CI, 98%-100%) and for HCV RNA quantification was 98% (95% CI, 96%-99%) and 100% (95% CI, 95%-100%).

CONCLUSIONS

Excellent diagnostic accuracy was observed across assays for detection of HCV RNA from finger-stick and DBS samples. The proportion of invalid results following Xpert HCV Viral Load Fingerstick testing highlights the importance of operator training and quality assurance programs.

Для цитирования: Catlett Beth, Hajarizadeh Behzad, Cunningham Evan, Wolfson-Stofko Brett, Wheeler Alice, Khandaker-Hussain Benazir, Feld Jordan J, Martró Elisa, Chevaliez Stéphane, Pawlotsky Jean Michel, Bharat Chrianna, Cunningham Philip H, Dore Gregory J, Applegate Tanya, Grebely Jason. Diagnostic Accuracy of Assays Using Point-of-Care Testing or Dried Blood Spot Samples for the Determination of Hepatitis C Virus RNA: A Systematic Review.. The Journal of infectious diseases. 2022. DOI: 10.1093/infdis/jiac049.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.