MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1093/europace/euu273

Медицинская библиотека · Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2014

Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon†.

Aytemir Kudret, Gurses Kadri Murat, Yalcin Muhammed Ulvi, Kocyigit Duygu, Dural Muhammet, Evranos Banu, Yorgun Hikmet, Ates Ahmet Hakan, Sahiner Mehmet Levent, Kaya Ergun Baris, Oto Mehmet Ali

СтатьяПеревод в очереди

Аннотация

AIMS: The second-generation cryoballoon (Arctic Front Advance™) (Arc-Adv-CB) has a redesigned injection system which distributes the refrigerant homogenously to the frontal balloon surface. The aim of this study was to compare the efficacy and safety of the Arc-Adv-CB and its predecessor (Arctic Front™) (Arc-CB) in patients who underwent pulmonary vein isolation (PVI) for atrial fibrillation (AF).

METHODS AND

RESULTS

Three hundred and six patients (55.35 ± 10.60 years, 47.05% male) were included in the study. A total of 1205 pulmonary veins were attempted for PVI with either Arc-CB or Arc-Adv-CB. The follow-up durations were 30 (23-38) and 10 (8-13) months in Arc-CB and Arc-Adv-CB groups, respectively (P < 0.001). When the blanking period was considered, freedom from AF after a single ablation procedure was 68.53 and 90.83% in patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively. The most frequent complication was transient phrenic nerve palsy (PNP) which occurred in five(2.54%) and nine(8.26%) of patients undergoing PVI with Arc-CB and Arc-Adv-CB, respectively (P = 0.040). Left atrial (LA) diameter (hazard ratio, HR: 3.552, 95% CI: 2.034-6.201, P < 0.001), smoking history (HR:1.643, 95% CI: 1.011-2.671, P = 0.045), persistent AF (HR:1.725, 95% CI: 1.021-2.915, P = 0.041), duration of AF (HR:1.039, 95% CI: 1.000-1.080, P = 0.047), and early AF recurrence (HR:2.399, 95% CI: 1.443-3.989, P < 0.001) were associated with increased late AF recurrence. On the other hand, intraprocedural vagal reactions (HR: 0.550, 95% CI: 0.331-0.915, P = 0.021) and Arc-Adv-CB use (HR: 0.441, 95% CI: 0.225-0.866, P = 0.017) were associated with lower late AF recurrence. Left atrial diameter (HR: 3.072, 95% CI: 1.646-5.732, P < 0.001), early AF recurrence (HR: 1.906, 95% CI: 1.103-3.291, P = 0.021), and Arc-Adv-CB use (HR: 0.472, 95% CI: 0.239-0.931, P = 0.030) were independent predictors for late AF recurrence.

CONCLUSION

Our study has shown that Arc-Adv-CB use is associated with lower late AF recurrences at the cost of an increased risk for PNP.

Для цитирования: Aytemir Kudret, Gurses Kadri Murat, Yalcin Muhammed Ulvi, Kocyigit Duygu, Dural Muhammet, Evranos Banu, Yorgun Hikmet, Ates Ahmet Hakan, Sahiner Mehmet Levent, Kaya Ergun Baris, Oto Mehmet Ali. Safety and efficacy outcomes in patients undergoing pulmonary vein isolation with second-generation cryoballoon†.. Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology. 2014. DOI: 10.1093/europace/euu273.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.