Borges Guilherme Almeida, Mesquita Marcelo Ferraz, Matias Luana Figueiredo da Silva, Barbin Thaís, Machado Leonardo Mendes Ribeiro, Barão Valentim Adelino Ricardo
Аннотация
This study aimed to assess the biomechanical behavior of reinforcement materials [cobalt chromium alloy (CoCr) and carbon fiber-reinforced polyether ether ketone (CFR-PEEK)] and their extensions (short: 15 mm and long: 25 mm) of single implant-retained mandibular overdentures (MO-1) by 3D finite element analysis (FEA), comparing them with MO-1 without a framework. Five models (CoCr-Short, CFR-PEEK-Short, CoCr-Long, CFR-PEEK-Long, and no framework) were created using the McNeel Rhinoceros 3D software, version 7.0. Stress distribution analysis by FEA was performed using the Optstruct solver, and a 30° oblique load (100 N) was applied in the anterior region (50 N on each central incisor). Biomechanical behavior was analyzed by overdenture displacement, maximum (MaxP) and minimum principal (MinP) stress, and von Mises stress. The MO-1 model 'without a framework' produced the largest dislocation, MinP stress on the mucosa, and MaxP stress in the cortical bone. Regardless of the extension of the framework, CFR-PEEK had minor MinP stress in the mucosa and lower overdenture displacement. The 'CoCr-Long' and 'CFR-PEEK-Long' models had higher von Mises stress on the implant housing, and MaxP stress on the O'ring nylon conventional implant and overdenture. The 'CoCr-Short' and ' CFR-PEEK-Short' models showed a greater tendency for tension concentration solely in the framework. The incorporation of a framework into MO-1 decreased stress concentration on the overdenture, resulting in lower stress on the attachment, mucosa, implant, and peri-implant bone, irrespective of the material used. The short framework, however, performed better biomechanically in MO-1, and it is therefore the most recommended option. CFR-PEEK showed favorable biomechanical outcomes, and is suggested for reinforcement of MO-1.