Bellini Barbara, Romano Vittorio, Zanda Greca, Iannopollo Gianmarco, De Ferrari Tommaso, Bijlsma Eva, Napoli Francesca, Vella Ciro, Gentile Domitilla, Ghizzoni Giulia, Ferri Luca Angelo, Russo Filippo, Ancona Marco Bruno, Ancona Francesco, Agricola Eustachio, Palmisano Anna, Esposito Antonio, Montorfano Matteo

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) disease is still burdened by a non-negligible rate of stroke and permanent pacemaker implantation (PPI). These suboptimal results, possibly related to the unique BAV anatomy, may suggest the use of a different sizing method in this setting. The aim of our study is to evaluate whether the application of the supra-annular LIRA method may improve clinical outcomes in this population.

METHODS

In this single-center retrospective study, we enrolled consecutive patients with severe aortic stenosis and raphe-type BAV undergone TAVR with the implantation of supra-annular self-expanding prostheses sized according to the LIRA method. The primary endpoint was the device success. Secondary endpoints were in-hospital and 30-day safety outcomes and 1-year clinical efficacy. All study endpoints were adjudicated according to the Valve Academic Research Consortium 3 criteria.

RESULTS

A total of 104 patients (mean age, 79.8 ± 5.83 years) were enrolled in our study. The mean Society of Thoracic Surgeons score was 4.96 ± 4.73%. Use of the LIRA method led to prosthesis downsizing in 85.6% of patients. Device success was 94.2%. All-cause death was 0%, conversion to surgery was 0%, and an extremely low rate of stroke (1.9%) and PPI (9.6%) was observed. The intended performance of the valve was attained in 96.1% of patients and it was maintained at 1-year follow-up. Clinical efficacy at 1 year was reached in 90.6% of patients.

CONCLUSIONS

The LIRA method represents an alternative option for prosthesis sizing in patients with type 1 and type 2 BAV undergoing TAVR with promising early and midterm outcomes.

Для цитирования: Bellini Barbara, Romano Vittorio, Zanda Greca, Iannopollo Gianmarco, De Ferrari Tommaso, Bijlsma Eva, Napoli Francesca, Vella Ciro, Gentile Domitilla, Ghizzoni Giulia, Ferri Luca Angelo, Russo Filippo, Ancona Marco Bruno, Ancona Francesco, Agricola Eustachio, Palmisano Anna, Esposito Antonio, Montorfano Matteo. Clinical Outcomes of Patients With Bicuspid Aortic Valve Undergoing a Targeted Transcatheter Aortic Valve Replacement Approach: The LIRA Method.. The Canadian journal of cardiology. 2024. DOI: 10.1016/j.cjca.2024.12.006.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.