MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1177/1591019917697473

Медицинская библиотека · Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2017

Malignant stroke in a ticagrelor non-responder as a complication following aneurysm treatment with the Pipeline Embolization Device™.

Ghamasaee Pegah, Carr Kevin, Johnson Jeremiah, Grandhi Ramesh

Клинический случайСтатьяПеревод в очереди

Аннотация

The Pipeline Embolization Device™ (PED; Covidien Neurovascular Inc, Irvine, CA, USA) is a flow-diverting stent often used for the endovascular treatment of large or giant, wide-necked intracranial aneurysms of the internal carotid artery. Because of the inherent thrombogenicity of intracranial stents, dual-antiplatelet therapy is initiated after placement, which has been shown to decrease morbidity and mortality related to perioperative ischemic events in neurointerventional procedures. However, in some series, as much as 50% of patients demonstrate clopidogrel non-responsiveness. In these non-responders, alternate agents such as ticagrelor can be used to achieve adequate anticoagulation. Compared with clopidogrel, a prodrug requiring Cytochrome P450 enzymolysis for activation, ticagrelor directly and reversibly inhibits the P2Y12 ADP receptor. The absorption of the prodrug and the formation of its active metabolite is comparatively quicker ( tmax 1.3-2 hours; 1.5-3 hours, respectively). To date, there have been no documented cases of ticagrelor non-responsiveness involving patients undergoing placement of flow-diverting stents or other endovascular neuro-interventional procedures.

Для цитирования: Ghamasaee Pegah, Carr Kevin, Johnson Jeremiah, Grandhi Ramesh. Malignant stroke in a ticagrelor non-responder as a complication following aneurysm treatment with the Pipeline Embolization Device™.. Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences. 2017. DOI: 10.1177/1591019917697473.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.