MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1002/jbio.201700097

Медицинская библиотека · Journal of biophotonics · 2017

Development of a 3-dimensional tissue lung phantom of a preterm infant for optical measurements of oxygen-Laser-detector position considerations.

Larsson Jim, Liao Peilang, Lundin Patrik, Krite Svanberg Emilie, Swartling Johannes, Lewander Xu Märta, Bood Joakim, Andersson-Engels Stefan

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

There is a need to further improve the clinical care of our most vulnerable patients-preterm infants. Novel diagnostic and treatment tools facilitate such advances. Here, we evaluate a potential percutaneous optical monitoring tool to assess the oxygen and water vapor content in the lungs of preterm babies. The aim is to prepare for further clinical studies by gaining a detailed understanding of how the measured light intensity and gas absorption signal behave for different possible geometries of light delivery and receiver. Such an experimental evaluation is conducted for the first time utilizing a specially developed 3-dimensional-printed optical phantom based on a geometry model obtained from computer tomography images of the thorax (chest) of a 1700-g premature infant. The measurements yield reliable signals for source-detector distances up to about 50 mm, with stronger gas absorption signals at long separations and positions related to the lower part of the lung, consistent with a larger relative volume of this. The limitations of this study include the omission of scattering tissue within the lungs and that similar optical properties are used for the wavelengths employed for the 2 gases, yielding no indication on the optimal wavelength pair to use.

Для цитирования: Larsson Jim, Liao Peilang, Lundin Patrik, Krite Svanberg Emilie, Swartling Johannes, Lewander Xu Märta, Bood Joakim, Andersson-Engels Stefan. Development of a 3-dimensional tissue lung phantom of a preterm infant for optical measurements of oxygen-Laser-detector position considerations.. Journal of biophotonics. 2017. DOI: 10.1002/jbio.201700097.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.