MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.jcms.2018.04.013

Медицинская библиотека · Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery · 2018

Laterocaudal approach to the inferior rim of the orbit.

Grandoch Andrea, Kreppel Matthias, Safi Ali-Farid, Zirk Matthias, Zöller Joachim E

СтатьяПеревод в очереди

Аннотация

PURPOSE: Fractures of the orbital floor and orbital rim are frequently treated in maxillofacial departments. Various approaches to the orbital floor are described in the literature. We present an investigation of a modified subciliary approach (laterocaudal approach) with respect to its feasibility and clinical outcome.

MATERIALS AND

METHODS

Our retrospective study investigated 130 well-documented cases of patients with orbital floor fractures who received surgical reconstruction using a laterocaudal approach, and compared the results with the current literature, with a focus on subciliary and transconjunctival approaches.

RESULTS

111 patients (85.4%) presented a Vancouver scar scale (VSS) of 0.14 patients (10.8%) had a VSS score of 1. No patients had a VSS of 2. Just five patients (3.8%) had a slight ectropium and therefore a VSS score of 3.

CONCLUSION

The laterocaudal approach can be safely performed and presents advantages over comparable techniques such as the subciliary and transconjunctival approaches if performed correctly.

Для цитирования: Grandoch Andrea, Kreppel Matthias, Safi Ali-Farid, Zirk Matthias, Zöller Joachim E. Laterocaudal approach to the inferior rim of the orbit.. Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery. 2018. DOI: 10.1016/j.jcms.2018.04.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.