BACKGROUND

Acute stent recoil has been often observed following stent delivery balloon deflation in coronary arteries and the recoil rate varies by stent design. Accordingly, the purpose of the present study was to evaluate the impact of stent designs on acute stent recoil after new generation drug-eluting stent implantation.

METHODS AND

RESULTS

A total of 154 lesions [56 treated with biolimus-eluting stent (BES), 46 with cobalt chromium everolimus-eluting stent (CoCr-EES), and 52 with platinum chromium everolimus-eluting stent (PtCr-EES)] were evaluated. Quantitative coronary angiography was used to measure the minimal lumen diameter (MLD). MLD1 was defined as a MLD of complete expansion of the last stent delivery balloon at the highest pressure. MLD2 was defined as a MLD immediately after the last stent delivery balloon deflation. Acute stent recoil was determined by the calculation as (MLD1-MLD2)/MLD1. Acute stent recoil was significantly higher in the CoCr-EES group versus the BES group and PtCr-EES group (10.1 ± 6.9%, 6.7 ± 5.5%, and 6.5 ± 4.8%, respectively, p = 0.01). Multivariate linear regression analysis demonstrated that the use of CoCr-EES and the number of stent delivery balloon inflations were independent predictors of acute stent recoil (r = 0.26, β = 0.21, p = 0.01 and r = -0.51, β = -0.58, p < 0.01, respectively).

CONCLUSION

Acute stent recoil occurred more frequently with the CoCr-EES compared with both BES and PtCr-EES. Strategies with multiple balloon inflation might be needed to overcome this recoil phenomenon.

Для цитирования: Ota Tomoyuki, Ishii Hideki, Sumi Takuya, Okada Takuya, Murakami Hisashi, Suzuki Susumu, Kada Kenji, Tsuboi Naoya, Murohara Toyoaki. Impact of coronary stent designs on acute stent recoil.. Journal of cardiology. 2014. DOI: 10.1016/j.jjcc.2014.02.013.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.