MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1080/14670100.2022.2067644

Медицинская библиотека · Cochlear implants international · 2022

Detection accuracy of soft tissue complications during remote cochlear implant follow-up.

Holtmann L C, Deuß E, Meyer M, Kaster F, Bastian T, Schleupner M C, Hagedorn E, Lang S, Arweiler-Harbeck D

СтатьяПеревод в очереди

Аннотация

PURPOSE: After cochlear implantation (CI), long-term follow-up is obligatory. Remote-care options which provide a standard of care comparable to in-person consultations, could be an attractive addition to a cochlear implant centre's portfolio. The aim of this study was to evaluate the accuracy of photographs of the skin covering the implant to reliably detect skin irritations or soft tissue complications.

METHODS

During routine follow-up consultations, 109 CI patients were examined in person and asked to take a photograph of the skin covering the implant using their smartphones. Photographs were digitally and remotely evaluated by two CI physicians who were blinded to the findings during the in-person examination.

RESULTS

In nine cases, skin abnormalities were detected by the CI physician upon in-person examination, seven of which required immediate treatment. Both digital evaluators reliably detected all treatment-requiring conditions. Overall, more skin irritations were suspected digitally compared to in-person examination. Without additional information from the patients' medical record, sensitivity was 100% and specificity was 63%; with additional information provided, sensitivity was 100%, and specificity increased to 65.3%.

CONCLUSION

Digital photographic assessment of the skin covering the implant is a highly sensitive method to detect skin irritations and could reduce the number of necessary in-person consultations.

Для цитирования: Holtmann L C, Deuß E, Meyer M, Kaster F, Bastian T, Schleupner M C, Hagedorn E, Lang S, Arweiler-Harbeck D. Detection accuracy of soft tissue complications during remote cochlear implant follow-up.. Cochlear implants international. 2022. DOI: 10.1080/14670100.2022.2067644.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.