MedElevator Войти в исследования
← Поиск публикаций

DOI 10.4244/eij-d-17-00632

Медицинская библиотека · EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2018

Combined use of coils and Onyx for transcatheter closure of coronary artery fistulae.

Li Pan, Xu Xudong, Zhang Zheng, Wang Feiyu, Wang Zhongkai, Chen Feng, Zhang Bili, Qin Yongwen, Chen Shaoping, Zhao Xianxian

СтатьяVideo-Audio MediaПеревод в очереди

Аннотация

AIMS: The aim of this study was to evaluate the safety and efficacy of combined endovascular coiling and Onyx embolisation in patients with a coronary artery fistula (CAF).

METHODS AND

RESULTS

Between September 2014 and September 2016, 26 patients with CAFs were enrolled in our study for attempted combined therapy using coils and Onyx. The mean age of patients was 64.0±9.5 years (range, 44-78 years). CAFs were large in 10 and medium in 16 patients. The mean number of coils used was 3.1±1.2 (range, two to six), and the average volume of Onyx was 0.4±0.1 ml (range, 0.2-0.6 ml). Immediate post-embolisation angiography demonstrated that complete occlusion was achieved in 23 patients (88.5%) and a small residual fistula was achieved in three patients (11.5%). Follow-up imaging (median, 11.5 months; range, nine to 20) revealed stable occlusion of CAF in 21 cases (80.8%), trivial recanalisation in four cases (15.4%), and large recanalisation in only one case (3.8%). Re-closure was performed in the patient with large recanalisation. During the follow-up period, no deaths, severe procedure-related complications, or new symptoms occurred.

CONCLUSIONS

In selected patients with CAF, transcatheter embolisation in combined therapy using coils and Onyx appears to be a valid option, providing a high success rate and low rate of recanalisation.

Для цитирования: Li Pan, Xu Xudong, Zhang Zheng, Wang Feiyu, Wang Zhongkai, Chen Feng, Zhang Bili, Qin Yongwen, Chen Shaoping, Zhao Xianxian. Combined use of coils and Onyx for transcatheter closure of coronary artery fistulae.. EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology. 2018. DOI: 10.4244/eij-d-17-00632.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.