MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1097/ta.0000000000002557

Медицинская библиотека · The journal of trauma and acute care surgery · 2020

Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta: Noninvasive evaluation using phase contrast magnetic resonance imaging.

Izawa Yoshimitsu, Hishikawa Shuji, Matsumura Yosuke, Nakamura Hiroyasu, Sugimoto Hideharu, Mato Takashi

СтатьяПеревод в очереди

Аннотация

BACKGROUND

Resuscitative endovascular balloon occlusion of the aorta (REBOA) is a viable resuscitation approach for a subdiaphragmatic injury that can regulate arterial blood flow. On the other hand, the evaluation of venous or portal venous blood flow during REBOA remains insufficient because invasive cannulation or exposure of the vessel may affect the blood flow, and Doppler echography is highly operator-dependent. However, phase contrast magnetic resonance imaging has enabled accurate evaluation and noninvasive measurement. This study aimed to investigate the change of venous and portal venous blood flow during REBOA in a porcine model.

METHODS

Seven pigs were anesthetized, and a REBOA catheter was placed. The blood flows of the inferior vena cava (IVC), hepatic vein (HV), portal vein (PV), and superior vena cava (SVC) were measured using phase contrast magnetic resonance imaging, in both the balloon deflated (no-REBOA) and fully balloon inflated (REBOA) states. Mean arterial pressure (MAP), central venous pressure, cardiac index, and systemic vascular resistance index were measured.

RESULTS

The blood flows of the suprahepatic, infrahepatic, and distal IVC, HV, and PV in the no-REBOA state were 1.40 ± 0.36 L·min, 0.94 ± 0.16 L·min, 0.50 ± 0.19 L·min, 0.060 ± 0.018 L·min, and 0.32 ± 0.091 L·min, respectively. The blood flow of each section in the REBOA condition was significantly decreased at 0.41 ± 0.078 (33% of baseline), 0.15 ± 0.13 (15%), 0.043 ± 0.034 (9%), 0.029 ± 0.017 (37%), and 0.070 ± 0.034 L·min (21%), respectively. The blood flow of the SVC increased significantly in the REBOA condition (1.4 ± 0.63 L·min vs. 0.53 ± 0.14 L·min [257%]). Mean arterial pressure, central venous pressure, cardiac index, and systemic vascular resistance index were significantly increased after REBOA inflation.

CONCLUSION

Resuscitative endovascular balloon occlusion of the aorta decreased blood flows of the IVC, HV, and PV and increased blood flow of the SVC. This result could be explained by the collateral flow from the lower body to the SVC. A better understanding of the effect of REBOA on the venous and portal venous systems may help control liver injury.

Для цитирования: Izawa Yoshimitsu, Hishikawa Shuji, Matsumura Yosuke, Nakamura Hiroyasu, Sugimoto Hideharu, Mato Takashi. Blood flow of the venous system during resuscitative endovascular balloon occlusion of the aorta: Noninvasive evaluation using phase contrast magnetic resonance imaging.. The journal of trauma and acute care surgery. 2020. DOI: 10.1097/ta.0000000000002557.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.