DOI 10.1097/01.pcc.0000256618.78382.da
Transient complete atrioventricular block after placement of a central venous catheter in a neonate.
Аннотация
OBJECTIVE
We present a case of trauma-induced complete atrioventricular block (transient) after placement of a central venous catheter.
DESIGN
Case report.
SETTING
Neonatal intensive care unit in a tertiary care children's hospital.
PATIENT: Review of the medical record and clinical course of a single premature infant.
INTERVENTIONS: Removal of central venous catheter, monitoring of the cardiac output exam, and serial monitoring of the arrhythmia profile.
MEASUREMENTS AND MAIN
RESULTS
Trauma-induced complete atrioventricular block from placement of the central venous catheter resolved in 9 days, obviating the need for pacemaker placement.
CONCLUSIONS
Complete atrioventricular block is an infrequent complication of central venous catheter placement and may require several days to resolve.