MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.prosdent.2013.12.004

Медицинская библиотека · The Journal of prosthetic dentistry · 2014

Should oral implants be splinted in a mandibular implant-supported fixed complete denture? A 3-dimensional-model finite element analysis.

Alvarez-Arenal Angel, Brizuela-Velasco Aritza, DeLlanos-Lanchares Hector, Gonzalez-Gonzalez Ignacio

СтатьяПеревод в очереди

Аннотация

STATEMENT OF PROBLEM: The design of a mandibular fixed complete denture can influence periimplant bone loss. However, the design that transfers the greatest stress to the periimplant bone is not well documented.

PURPOSE: The purpose of this study was to assess the stress distribution associated with splinted and nonsplinted implant-supported mandibular fixed complete denture designs.

MATERIAL AND

METHODS

Three-dimensional finite element models simulating 6 osseointegrated implants were created in the mandible to support a cobalt-chromium alloy and feldspathic porcelain veneering framework. One model simulated a 1-piece framework, and the other models simulated 2-piece and 3-piece frameworks. Axial and oblique loads were applied to the frameworks.

RESULTS

For all the models, the greatest stress values were recorded in the periimplant bone of posterior implants, with differences between the left and right sides. The axial load transferred greater stress values to the periimplant bone than did the oblique load. The lowest periimplant bone stress values were observed in the 3-piece framework model at all implant locations, with the exception of implants placed in the canine region.

CONCLUSIONS

A framework separated into 3 pieces transfers the least stress to the periimplant bone.

Для цитирования: Alvarez-Arenal Angel, Brizuela-Velasco Aritza, DeLlanos-Lanchares Hector, Gonzalez-Gonzalez Ignacio. Should oral implants be splinted in a mandibular implant-supported fixed complete denture? A 3-dimensional-model finite element analysis.. The Journal of prosthetic dentistry. 2014. DOI: 10.1016/j.prosdent.2013.12.004.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.