Аннотация

Na/Ca exchanger activity is important for calcium extrusion from the cardiomyocyte cytosol during repolarization. Animal models exhibiting altered Na/Ca exchanger expression display abnormal cardiac phenotypes. In humans, elevated Na/Ca exchanger expression/activity is linked with pathophysiological conditions including arrhythmia and heart failure. Whereas the molecular mechanisms underlying Na/Ca exchanger biophysical properties are widely studied and generally well characterized, the cellular pathways and molecular partners underlying the specialized membrane localization of Na/Ca exchanger in cardiac tissue are essentially unknown. In this report, we present the first direct evidence for a protein pathway required for Na/Ca exchanger localization and stability in primary cardiomyocytes. We define the minimal structural requirements on ankyrin-B for direct Na/Ca exchanger interactions. Moreover, using ankyrin-B mutants that lack Na/Ca exchanger binding activity, and primary cardiomyocytes with reduced ankyrin-B expression, we demonstrate that direct interaction with the membrane adaptor ankyrin-B is required for the localization and post-translational stability of Na/Ca exchanger 1 in neonatal mouse cardiomyocytes. These results raise exciting new questions regarding potentially dynamic roles for ankyrin proteins in the biogenesis and maintenance of specialized membrane domains in excitable cells.

Для цитирования: Cunha Shane R, Bhasin Naina, Mohler Peter J. Targeting and stability of Na/Ca exchanger 1 in cardiomyocytes requires direct interaction with the membrane adaptor ankyrin-B.. The Journal of biological chemistry. 2006. DOI: 10.1074/jbc.m607096200.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.