MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1186/s10195-025-00857-8

Медицинская библиотека · Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2025

Diagnostic work-up in periprosthetic joint infections of the knee: can the albumin-to-globulin ratio be a screening tool?

De Mauro Domenico, Ascione Tiziana, Festa Enrico, Marasco Lucrezia, Leggieri Filippo, Rosito Sara, Innocenti Matteo, Di Pace Edoardo, Balato Giovanni

СтатьяПеревод в очереди

Аннотация

BACKGROUND

This study aimed to assess the most appropriate thresholds for albumin-to-globulin ratio (AGR) in patients who had a suspected periprosthetic knee infection. Furthermore, the diagnostic accuracy of the proposed threshold was evaluated.

MATERIALS AND

METHODS

Between January 2020 and April 2022, patients with failed or painful knee arthroplasty who were admitted to a tertiary referral institution undergoing the standardized diagnostic protocol to identify those with a periprosthetic joint infection (PJI) were analyzed. The 2018 International Consensus Meeting (ICM) criteria were used to classify patients with PJIs and aseptic joints. Sensitivity, specificity, positive predictive value, negative predictive value, and the area under the receiver operating characteristic (ROC) curve (AUC) of AGR were calculated to define the test's diagnostic accuracy.

RESULTS

The ROC curve showed that the optimal cutoff value of AGR was 1.43. AGR registered a sensitivity of 95% (95% CI 91-197%), a specificity of 63% (95% CI 56-69%), a positive predictive value of 75% (95% CI 69-81%), and a negative predictive value of 91% (95% CI 86-94%). Receiver operator curve analysis demonstrated an AUC of 0.85 (95% CI 0.77-0.88). Although body mass index (BMI), uremia, glutamic-oxaloacetic transaminase (GOT), international normalized ratio (INR), and alkaline phosphatase showed significant differences between the false positive cases and those cases affected by aseptic failure with AGR higher than 1.43, indicating potential confounding effects (p < 0.05), no parameter was found to be a significant predictor of false positives cases (p > 0.05).

CONCLUSIONS

For its high sensitivity, AGR showed potential as a screening tool for detecting infections in PJI diagnostics.

LEVEL OF EVIDENCE: III.

Для цитирования: De Mauro Domenico, Ascione Tiziana, Festa Enrico, Marasco Lucrezia, Leggieri Filippo, Rosito Sara, Innocenti Matteo, Di Pace Edoardo, Balato Giovanni. Diagnostic work-up in periprosthetic joint infections of the knee: can the albumin-to-globulin ratio be a screening tool?. Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology. 2025. DOI: 10.1186/s10195-025-00857-8.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.