MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1021/acs.analchem.6b04623

Медицинская библиотека · Analytical chemistry · 2017

High-Speed Quantitative UPLC-MS Analysis of Multiple Amines in Human Plasma and Serum via Precolumn Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate: Application to Acetaminophen-Induced Liver Failure.

Gray Nicola, Zia Rabiya, King Adam, Patel Vishal C, Wendon Julia, McPhail Mark J W, Coen Muireann, Plumb Robert S, Wilson Ian D, Nicholson Jeremy K

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

A targeted reversed-phase gradient UPLC-MS/MS assay has been developed for the quantification /monitoring of 66 amino acids and amino-containing compounds in human plasma and serum using precolumn derivatization with 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AccQTag Ultra). Derivatization of the target amines required minimal sample preparation and resulted in analytes with excellent chromatographic and mass spectrometric detection properties. The resulting method, which requires only 10 μL of sample, provides the reproducible and robust separation of 66 analytes in 7.5 min, including baseline resolution of isomers such as leucine and isoleucine. The assay has been validated for the quantification of 33 amino compounds (predominantly amino acids) over a concentration range from 2 to 20 and 800 μM. Intra- and interday accuracy of between 0.05 and 15.6 and 0.78-13.7% and precision between 0.91 and 16.9% and 2.12-15.9% were obtained. A further 33 biogenic amines can be monitored in samples for relative changes in concentration rather than quantification. Application of the assay to samples derived from healthy controls and patients suffering from acetaminophen (APAP, paracetamol)-induced acute liver failure (ALF) showed significant differences in the amounts of aromatic and branched chain amino acids between the groups as well as a number of other analytes, including the novel observation of increased concentrations of sarcosine in ALF patients. The properties of the developed assay, including short analysis time, make it suitable for high-throughput targeted UPLC-ESI-MS/MS metabonomic analysis in clinical and epidemiological environments.

Для цитирования: Gray Nicola, Zia Rabiya, King Adam, Patel Vishal C, Wendon Julia, McPhail Mark J W, Coen Muireann, Plumb Robert S, Wilson Ian D, Nicholson Jeremy K. High-Speed Quantitative UPLC-MS Analysis of Multiple Amines in Human Plasma and Serum via Precolumn Derivatization with 6-Aminoquinolyl-N-hydroxysuccinimidyl Carbamate: Application to Acetaminophen-Induced Liver Failure.. Analytical chemistry. 2017. DOI: 10.1021/acs.analchem.6b04623.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.