MedElevator Войти в исследования
← Поиск публикаций

DOI 10.7759/cureus.43451

Медицинская библиотека · Cureus · 2023

Critical Care Experience With Clinical Cerebral Autoregulation Testing in Adults With Traumatic Brain Injury.

Kunapaisal Thitikan, Vavilala Monica S, Moore Anne, Theard Marie A, Lele Abhijit V

СтатьяПеревод в очереди

Аннотация

To describe the setting, feasibility, and safety of static cerebral autoregulation testing in critically injured adults with traumatic brain injury (TBI).

Methods

We reviewed static autoregulation testing using transcranial Doppler (TCD) ultrasound in patients > 18 years with TBI ICD codes between January 1, 2014, and December 31, 2021. Adverse events during testing were defined as systemic hypertension (systolic blood pressure (SBP>180 mmHg), bradycardia (HR<40 bpm), and high ICP (>30 mmHg). Impaired and absent cerebral autoregulation was defined as an autoregulatory index (ARI) <0.4 and ARI 0, respectively. We characterized prescribed changes in intracranial pressure (ICP) and cerebral perfusion pressure (CPP) targets by autoregulation testing results.

Results

A total of 135 patients, median age 31 (interquartile range (IQR) 24, 43) years, 71.9% male, admission Glasgow coma scale (GCS) score 3 (IQR 3, 5.5), and 70.9% with subdural hematoma from severe (GCS 3-8; 133 (98.5%)) and moderate (GCS 9-12; 2 (1.5%)) TBI, underwent 309 attempted testing. All patients were mechanically ventilated and had ICP monitoring; 246 (80%) had brain tissue oxygen monitoring, and 68 (22%) had an external ventricular drain. The median number of autoregulation tests was two (range 1-3) tests/patient, and the median admission to the first test time was two days (IQR 1, 3). Of 55 (17.8%) tests not completed, systemic hypertension (32, 10.4%), intracranial hypertension (10, 3.2%), and bradycardia (3, 0.9%) were transient. Fifty-three (51%) of the first (n=104) autoregulation tests showed impaired/absent cerebral autoregulation. Impaired/absent autoregulation results at the first test were associated with repeat cerebral autoregulation testing (RR 2.25, 95% CI [1.40-3.60], p=0.0007) than intact cerebral autoregulation results. Pre-testing cerebral hemodynamic targets were maintained (n=131; 86.8%) when cerebral autoregulation was impaired (n=151; RR 1.49, 95% CI [1.25-1.77], p<0.0001). However, 15 (9.9%) test results led to higher ICP targets (from 20 mmHg to 25 mmHg), 5 (3.3%) results led to an increase in CPP target (from 60 mmHg to 70 mmHg), and five out of 131 (3.8%) patients underwent decompressive craniectomy and placement of an external ventricular drain. Intact cerebral autoregulation results (n=43/103, 41.7%) were associated with a change in ICP targets from 20 mmHg to 25 mmHg (RR 3.15, 95% CI [1.97-5.03], p<0.0001).

Conclusions

Static cerebral autoregulation testing was feasible, safe, and useful in individualizing the care of patients with moderate-severe TBI receiving multimodal neuromonitoring. Testing results guided future testing, cerebral hemodynamic targets, and procedural decisions. Impaired cerebral autoregulation was very common.

Для цитирования: Kunapaisal Thitikan, Vavilala Monica S, Moore Anne, Theard Marie A, Lele Abhijit V. Critical Care Experience With Clinical Cerebral Autoregulation Testing in Adults With Traumatic Brain Injury.. Cureus. 2023. DOI: 10.7759/cureus.43451.
Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.