MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1007/s00586-019-06054-6

Медицинская библиотека · European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2019

Augmented reality and artificial intelligence-based navigation during percutaneous vertebroplasty: a pilot randomised clinical trial.

Auloge Pierre, Cazzato Roberto Luigi, Ramamurthy Nitin, de Marini Pierre, Rousseau Chloé, Garnon Julien, Charles Yan Philippe, Steib Jean-Paul, Gangi Afshin

СтатьяРандомизированное исследованиеПеревод в очереди

Аннотация

PURPOSE: To assess technical feasibility, accuracy, safety and patient radiation exposure of a novel navigational tool integrating augmented reality (AR) and artificial intelligence (AI), during percutaneous vertebroplasty of patients with vertebral compression fractures (VCFs).

MATERIAL AND

METHODS

This prospective parallel randomised open trial compared the trans-pedicular access phase of percutaneous vertebroplasty across two groups of 10 patients, electronically randomised, with symptomatic single-level VCFs. Trocar insertion was performed using AR/AI-guidance with motion compensation in Group A, and standard fluoroscopy in Group B. The primary endpoint was technical feasibility in Group A. Secondary outcomes included the comparison of Groups A and B in terms of accuracy of trocar placement (distance between planned/actual trajectory on sagittal/coronal fluoroscopic images); complications; time for trocar deployment; and radiation dose/fluoroscopy time.

RESULTS

Technical feasibility in Group A was 100%. Accuracy in Group A was 1.68 ± 0.25 mm (skin entry point), and 1.02 ± 0.26 mm (trocar tip) in the sagittal plane, and 1.88 ± 0.28 mm (skin entry point) and 0.86 ± 0.17 mm (trocar tip) in the coronal plane, without any significant difference compared to Group B (p > 0.05). No complications were observed in the entire population. Time for trocar deployment was significantly longer in Group A (642 ± 210 s) than in Group B (336 ± 60 s; p = 0.001). Dose-area product and fluoroscopy time were significantly lower in Group A (182.6 ± 106.7 mGy cm2 and 5.2 ± 2.6 s) than in Group B (367.8 ± 184.7 mGy cm2 and 10.4 ± 4.1 s; p = 0.025 and 0.005), respectively.

CONCLUSION

AR/AI-guided percutaneous vertebroplasty appears feasible, accurate and safe, and facilitates lower patient radiation exposure compared to standard fluoroscopic guidance. These slides can be retrieved under Electronic Supplementary Material.

Для цитирования: Auloge Pierre, Cazzato Roberto Luigi, Ramamurthy Nitin, de Marini Pierre, Rousseau Chloé, Garnon Julien, Charles Yan Philippe, Steib Jean-Paul, Gangi Afshin. Augmented reality and artificial intelligence-based navigation during percutaneous vertebroplasty: a pilot randomised clinical trial.. European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society. 2019. DOI: 10.1007/s00586-019-06054-6.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.