Amplicon-based long-read sequencing for accurate CYP2D6 gene deletion and duplication detection using CYP2D7 as a reference gene.

Tesfamicael Kiflu Gebremicael, Musker Michael, Adelson David L, Lewis Martin David

СтатьяПеревод в очереди

Аннотация

We developed an amplicon-based long-read sequencing approach that enables simultaneous detection of CYP2D6 single-nucleotide variants (SNVs) and copy-number variations (CNVs) in a single reaction. The SNVs of the two pseudogenes, CYP2D7 and CYP2D8, were also comprehensively characterized. CYP2D6 CNVs were inferred using CYP2D7 as a reference gene, integrating read-depth measurements with allele-frequency (AF) ratios. The entire CYP2D locus ( ~ 30.2Kb) and the three homologous genes separately (6.3-6.6Kb) were sequenced using Oxford Nanopore sequencing. Our analysis identified 21 CYP2D7 and 17 CYP2D8 unique haplotypes, and 57% of the SNVs detected in the pseudogenes had nucleotides corresponding to CYP2D6 reference nucleotides. A total of 36 variants found within the pseudogenes have also been annotated as functional variants in the CYP2D6 gene. The combined CYP2D6:CYP2D7 read-count ratio and reference-to-alternative alleles AF ratio accurately predicted CYP2D6 CNV status. This method is simple and rapid, making it potentially suitable for clinical implementation of pharmacogenomics.

Для цитирования: Tesfamicael Kiflu Gebremicael, Musker Michael, Adelson David L, Lewis Martin David. Amplicon-based long-read sequencing for accurate CYP2D6 gene deletion and duplication detection using CYP2D7 as a reference gene.. The pharmacogenomics journal. 2026. DOI: 10.1038/s41397-026-00429-x.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.