MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/j.ajic.2026.06.012

Медицинская библиотека · American journal of infection control · 2026

Overestimation of personal hand hygiene performance and barriers to hand hygiene among healthcare providers.

Srikanth Sonia, Ching Patrick R, Rittmann Barry, Pedersen Laura, Wooten Ryan, Olkonen Tina, Cooper Kaila, Doll Michelle

СтатьяПеревод в очереди

Аннотация

INTRODUCTION

Hand hygiene (HH) performance in our facility declined during the COVID-19 pandemic and failed to return to baseline despite a widespread education campaign and increased HH rounding. To better understand provider perceptions and inform future interventions, we conducted a survey examining self-evaluation of HH performance.

METHODS

The survey assessed perceived HH performance relative to peers, opportunities for improvement, factors causing variation in personal HH practice (workload/acuity, time of day, and patient characteristics), and burnout using a validated, single-item scale. Surveys were conducted in-person with clinical providers on high-performing and lower-performing units. Non-clinical staff were excluded. Self-perception of performance was compared against other variables using the Kruskal-Wallis test, using SAS 9.4, Cary, NC.

RESULTS

One hundred surveys were completed. The majority of those surveyed believed themselves to be in the top quartile of HH performers (87%). The actual HH compliance measured on these 4 units for 1/2024-11/2024 was 65% based on 7,436 directly-observed opportunities. No one selected bottom quartiles. There was no difference in perceived performance by unit (P = .4006), years of experience (P = .9679), or burnout (P = .2621).

CONCLUSION

HH performance was perceived to be better than average by the majority of inpatient healthcare providers surveyed, despite data from these units indicating opportunities. Further improvement in HH will be difficult without efforts to move perception closer to reality for individual healthcare providers.

Для цитирования: Srikanth Sonia, Ching Patrick R, Rittmann Barry, Pedersen Laura, Wooten Ryan, Olkonen Tina, Cooper Kaila, Doll Michelle. Overestimation of personal hand hygiene performance and barriers to hand hygiene among healthcare providers.. American journal of infection control. 2026. DOI: 10.1016/j.ajic.2026.06.012.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.