MedElevator Войти в исследования
← Поиск публикаций

DOI 10.1016/s0002-9394(14)72064-1

Медицинская библиотека · American journal of ophthalmology · 1996

Visual field defects after macular hole surgery.

Boldt H C, Munden P M, Folk J C, Mehaffey M G

Клинический случайСтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

PURPOSE: To describe a group of patients with dense visual field defects following macular hole surgery.

METHODS

Nine (7%) of 125 patients reviewed noted onset of dense visual field defects following uncomplicated vitrectomy with gas-fluid exchange for the treatment of macular hole. Patient records were reviewed to investigate the etiology of these defects.

RESULTS

Eight (89%) of nine eyes that had surgery for macular hole developed dense, wedge-shaped visual field defects in the temporal periphery. One eye had an inferonasal wedge-shaped defect extending to fixation. Seven (78%) of nine eyes had generalized or focal narrowing of the retinal arteriole extending into the area of retina corresponding to the visual field defect, and five (56%) of nine eyes developed mild to moderate segmental nasal optic disk pallor. Postoperative fluorescein angiography disclosed one eye with delayed filling of the retinal arteriole extending into the area of retina corresponding to the visual field defect. Vitrectomy specimens showed no evidence of nerve fiber layer or internal limiting membrane in eight (89%) of nine eyes.

CONCLUSIONS

Visual field defects can occur following vitrectomy and gas-fluid exchange for macular hole. The most common visual field defect is dense and wedge-shaped and involves the temporal visual field. Although unclear, the etiology may involve trauma to the peripapillary retinal vasculature or nerve fiber layer during elevation of the posterior hyaloid or during aspiration at the time of air-fluid exchange, followed by compression and occlusion of the retinal peripapillary vessels during gas tamponade.

Для цитирования: Boldt H C, Munden P M, Folk J C, Mehaffey M G. Visual field defects after macular hole surgery.. American journal of ophthalmology. 1996. DOI: 10.1016/s0002-9394(14)72064-1.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.