Interlaboratory comparison of a multiplex immunoassay that measures human serum IgG antibodies against six-group B streptococcus polysaccharides.

Le Doare Kirsty, Gaylord Michelle A, Anderson Annaliesa S, Andrews Nick, Baker Carol J, Bolcen Shanna, Felek Arif, Giardina Peter C, Grube Christopher D, Hall Tom, Hallis Bassam, Izu Alane, Madhi Shabir A, Maniatis Pete, Matheson Mary, Mawas Fatme, McKeen Andrew, Rhodes Julia, Alston Bailey, Patel Palak, Schrag Stephanie, Simon Raphael, Tan Charles Y, Taylor Stephen, Kwatra Gaurav, Gorringe Andrew

СтатьяПоддержка исследования: вне правительства СШАПеревод в очереди

Аннотация

Measurement of IgG antibodies against group B streptococcus (GBS) capsular polysaccharide (CPS) by use of a standardized and internationally accepted multiplex immunoassay is important for the evaluation of candidate maternal GBS vaccines in order to compare results across studies. A standardized assay is also required if serocorrelates of protection against invasive GBS disease are to be established in infant sera for the six predominant GBS serotypes since it would permit the comparison of results across the six serotypes. We undertook an interlaboratory study across five laboratories that used standardized assay reagents and protocols with a panel of 44 human sera to measure IgG antibodies against GBS CPS serotypes Ia, Ib, II, III, IV, and V. The within-laboratory intermediate precision, which included factors like the lot of coated beads, laboratory analyst, and day, was generally below 20% relative standard deviation (RSD) for all six serotypes, across all five laboratories. The cross-laboratory reproducibility was < 25% RSD for all six serotypes, which demonstrated the consistency of results across the different laboratories. Additionally, anti-CPS IgG concentrations for the 44-member human serum panel were established. The results of this study showed assay robustness and that the resultant anti-CPS IgG concentrations were reproducible across laboratories for the six GBS CPS serotypes when the standardized assay was used.

Для цитирования: Le Doare Kirsty, Gaylord Michelle A, Anderson Annaliesa S, Andrews Nick, Baker Carol J, Bolcen Shanna, Felek Arif, Giardina Peter C, Grube Christopher D, Hall Tom, Hallis Bassam, Izu Alane, Madhi Shabir A, Maniatis Pete, Matheson Mary, Mawas Fatme, McKeen Andrew, Rhodes Julia, Alston Bailey, Patel Palak, Schrag Stephanie, Simon Raphael, Tan Charles Y, Taylor Stephen, Kwatra Gaurav, Gorringe Andrew. Interlaboratory comparison of a multiplex immunoassay that measures human serum IgG antibodies against six-group B streptococcus polysaccharides.. Human vaccines & immunotherapeutics. 2024. DOI: 10.1080/21645515.2024.2330138.

Предметные рубрики MeSH

Подготовка и перевод публикации
Обработка статьи · этапы, ошибки и управление
Загрузка состояния…

История · было → стало

Состояние обновляется каждые 5 секунд, пока блок открыт. Процент показывается только там, где известен объём работы. Пауза останавливает продолжение этапа; текущий запрос к источнику может завершиться.

Тип публикации указан по данным источника. Уровень доказательности автоматически не присваивается.